logomov2s.gif (46942 bytes)

Line o' site

Hz Multimeter

4 1/2 Digit True RMS Multimeter
T7014

This True RMS digital multimeter has a 4 1/2 digit display.  True RMS readings for ACA and ACV.   Comes with instructions, test probes, spare fuse and a 9-Volt battery. 

SPECIFICATIONS

DC Voltage

Range 200mV, 2V, 20V, 200V, 600V
Resolution 0.01mV, 0.1mV, 1mV, 10mV, 0.1V
Accuracy ?(0.1 + 2 digit) - 20mV
?(0.2 + 2 digit) - 2V, 20V, 200V, 600V
Input Impedance 10 M ohm
Overload Protection 00 DCV, 350 ACV-200mV range
000 DCV, 800 ACV-others

AC Voltage (True RMS)

Range 200mV, 2V, 20V, 200V, 600V
Resolution 0.01mV, 0.1mV, 1mV, 10mV, 0.1V
Accuracy ?(0.8% + 10 digit) - 200mV, 2V, 20V,  200V, 600V
(tested under 50-60Hz)
Input Impedance 10 M ohm
Overload protection 00 DCV, 350 ACV-200mV range
000 DCV, 800 ACV-others

DC Current

Range 200uA, 2mA, 20mA, 200mA,10A
Resolution 10nA, 100nA, 1uA, 10uA, 1mA
Accuracy ?(0.5% of reading + 5 digits)- 200uA, 2mA, 20mA
?(0.8% of reading + 10 digits)- 200mA
?(2% of reading + 5 digits)- 10A
Overload Protection 200uA, 2mA, 20mA, 200mA:  0.5A fuse protection
10A range: Max. 10A (no fuse)

AC Current (True RMS)

Range  200uA, 2mA, 20mA, 200mA, 10A 
Resolution 10nA, 100nA, 1uA, 10uA,  100uA, 1mA
Accuracy ?(0.8% of reading + 10 digits)- 200uA, 2mA, 20mA, 200mA
?(2% of reading + 10 digits)- 10A
Overload Protection 200uA, 2mA, 20mA, 200mA:  0.5A fuse protection
10A range: Max. 10A (no fuse)

OHMS

Range 200/2k/20k/200k/2M/20M ohm
Resolution 0.01/0.1/1/10/100/1k ohm
Accuracy ?(0.5% of reading + 5 digits) - 200 ohm
?(0.3% of reading + 5 digits) - 2k, 20k, 200k, 2M ohm
?(0.8% of reading + 3 digits), - 20M ohm

Diode Check

Resolution 0.1mV
Range Approx. forward voltage (VF), good/defect test

Transistor (PNP or NPN) hFE

Range 0-1000hFE
Dimensions  185 x 84 x 39mm
(7.3" x 3.3" x 1.5")
Weight 320 grams (11.3 ounces)
Display 4 1/2 digits, 15mm (0.5") LCD
Sampling Rate 0.4 seconds
Battery 9V battery 
Operating Temperature 0-50C (32-122F)
Operating Humidity Less than 80%
Accessories 9V battery, instruction manual, testing cables, spare fuse

 

Line o' site


Send comments to: jsi@jsits.com