MAIN MENU

CATALOG INDEX
BY ALPHABETICAL
ORDER

CATALOG INDEX
BY DEPARTMENT

For more inf o:
JSi@jsits.com

- [ Model 9200 Dissolved
Oxygen Meter ]
- [ Model 9300 Dissolved
Oxygen Meter ]
- [ YSI 5000 Dissolved
Oxygen Intrument ]
- [ YSI 5100 Dissolved
Oxygen Instrument ]
- [ YSI 550 DO Instrument ]
- [ YSI 52 DO Meter ]
- [ YSI 55 DO Meter ]
- [ YSI 58 DO Meter ]
- [ YSI 85 DO and
Conductivity Meter ]
- [ YSI 95 DO Meter ]

YSI 550 DO Instrument

ysi550_do_instrument.jpg (11077 octets)¾ß¿Ü¿¡¼­ÀÇ °­·ÂÇÑ ¼º´É

¿ëÁ¸»ê¼Ò¸¦ ÃøÁ¤Çϴµ¥ ÀÖ¾î
¾ß¿Ü¿¡¼­ °­·ÂÇÑ ¼º´ÉÀ» ¹ßÈÖÇÏ´Â
°èÃø±â¸¦ ã´Â´Ù¸é »õ·Î °³¹ßµÈYSI 55DO °èÃø±â°¡ ¹Ù·Î ±×¸ðµ¨À̶ó ÇÒ¼ö ÀÖ½À´Ï´Ù.
¹æ¼ö±â´É°ú Ãæ°Ý¿¡ °­ÇÑ °ß°íÇÑ
ÄÉÀ̽º·Î µÇ¾î ÀÖÀ¸¸ç Çõ½ÅÀûÀÎ
¾ß¿Ü¼³Ä¡¿ë DOÀü±Ø¸ðµâÀ» °®°í ÀÖ°í
ÀÌ¹Ì ¼º´ÉÀÌ ÀÔÁõµÈ YSIÀÇ polarographicÅ×Å©³î·ÎÁö°¡ Àû¿ëµÇ¾î ÀÖ¾î ¿ëÁ¸»ê¼Ò¿Í ¿ÂµµÀÇ Á¤È®ÇÑ ÃøÁ¤ÀÌ °¡´ÉÇÏ¸ç ±×Á¤È®¼ºÀ¸·Î ÀÎÇØ
Àü¼¼°èÀÇ Ç¥ÁØÀÌ µÇ´Â °èÃø±â ÀÔ´Ï´Ù.
  • Waterproof! Meets IP67 specifications
  • Field-replaceable DO electrode modules
  • Screw-on cap membranes
  • Over 2000 hours battery life
  • Calibrate in either mg/L or % saturation
  • User-selectable temperature units (°C or °F)
  • 12- and 25-foot cable lengths
  • Three-year warranty on the instrument and one-year on the DO module!

Packed with features
Measurements are fast and easy with one-hand operation, an easy-to-use backlit display, low battery indicator, automatic push-button calibration, and a weighted, quick-sinking probe. The YSI 550 DO has a built-in calibration chamber, direct salinity, and altitude compensation. The instrument provides simultaneously readings of oxygen and temperature. Dissolved oxygen readings are automatically compensated for temperature.

Specifications

  • Medium: Fresh, sea, or polluted water
  • Range: 0 to 200% air saturation
    0 to 20 mg/L
  • Resolution: 0.1% air saturation
    0.01 mg/L
  • Accuracy
    ?% air saturation or ?% of reading, whichever is greater
    ?.3 mg/L or ?% or reading, whichever is greater
  • Dissolved Oxygen Sensor: Steady-state polarographic
  • Dissolved Oxygen Probe: Field-replaceable module
  • Temperature units: Celsius or fahrenheit, user selectable
  • Temperature specifications
    Range: -5 to 45°C
    Resolution: 0.1°C
    Accuracy: ?.3°C
  • Parameter compensation: Automatic temperature compensation for dissolved oxygen, automatic salinity compensation for dissolved oxygen, altitude compensation for calibration
  • Size: 4.7 in. width; 9 in. length (11.9 cm x 22.9 cm)
  • Weight with batteries: 2 lb (0.91 kg)
  • Power: 4 alkaline C cell
  • Battery life: Over 2000 hours at 25°C
  • Cables: 12 or 25 foot lengths
  • Other features
    • Waterproof to IP67
    • High impact resistance
    • Push-button calibration
    • Built-in calibration chamber
    • Large, backlit display
    • Low battery indicator on display
    • CE compliance
  • Warranty:
    3-year for the instrument
  • 1-year for the DO module

Easy to use
YSI 559 Replacement Dissolved Oxygen electrode modules enable quick changes in the field. Simply detach the safety cap, then unscrew and replace the DO electrode. It's fast, easy, and requires no training.