MAIN MENU

CATALOG INDEX
BY ALPHABETICAL
ORDER

CATALOG INDEX
BY DEPARTMENT

For more info:
JSi@jsits.com

- [ Air Velocity
Temperature Relative
Humidity in One Meter
]
- [
VelociCalc Air Velocity
meters ]
- [
VelociCalc Plus
multi-parametter
ventilation meters ]

VelociCalc 회전 바람개비 풍속계(Rotating Vane Anemometer)

velocicalc_air_velicity_meters.jpg (7144 octets)Models 8322 ,8324 VELOCICALC ,VELOCICALC Plus Rotating Vane Anemometers

  •  


용도

  • 히팅, 쿨링 코일 분석
  • 휠터면 속도 측정
  • 디퓨저, 그릴 측정
  • 실내 공기 측정
  • 흄 후드 속도 측정

 

Models 8322, 8324 VELOCICALC
사양

속도(전 모델)
Range (100 mm head): 0.25 to 30 m/s (50 to 6,000 ft/min)
Accuracy (100 mm head): ±1.0% of reading or ±0.015 m/s (±3 ft/min)
whichever is greater
Range (35 mm head): 0.4 to 30 m/s (80 to 6,000 ft/min)
Accuracy (35 mm head): ±1.5% of reading or ±0.025 m/s (±5 ft/min)
whichever is greater

온도(전 모델)
Range: 0 to 80.3°C (32 to 176°F)
Resolution: 0.1°C (0.1°F)
Accuracy: ±0.5°C (±1.0°F)

온도 측정 범위 (전 모델)
Operating (electronics): 5 to 45°C (40 to 113°F)
Operating (probe): 0 to 80°C (32 to 176°F)
Storage: -20 to 60°C (-4 to 140°F)

부피 흐름(전 모델)
Range1: 0 to 1,230,000 l/s, 0 to 4,360,000 m3
(0 to 2,604,000 ft3/hr)

덕트 사이즈( 전 모델)
Range: 1 to 635 cm in increments of 0.1 cm (1 to 250
inches in increments of 0.1 inches)

평균치 계산(전 모델)
Range: Up to 255 values each of velocity, temperature

데이터 저장(Model 8324)
Range: Up to 2849 samples and 1,000 test ids
Intervals: 1, 2, 5, 10, 15, 20, 30 and 60 sec and
2, 5, 10, 15, 20, 30 60 min

Time Constant (전 모델)
Intervals: 1, 2, 5, 10, 15, and 20 sec

외형 (전 모델)
Size Measurements: 10 cm x 16.8 cm x 3.8 cm
(3.9 in. x 6.6 in. x 1.5 in.)

바람개비 헤드 치수(전 모델)
Standard Head Diameter: 100.0 mm (4 in.)
Optional Head Diameter: 35.0 mm (1.4 in.)

무게(전 모델)
Weight (with batteries): 0.68 kg (1.5 lbs)

디스플레이 치수(전 모델)
Display: 4-digit LCD, 15 mm (0.6 in.) digit height

전원(전 모델)
Requirements: Four AA-size batteries (included) or AC
adapter (optional)

프린터 인터페이스
Type: Serial
Baud Rate: 1200

 

 

8322

8324

Velocity

x

x

Temperature

x

x

Volumetric Flowrate

x

x

Sweep Mode

x

x

Averaging Capability

x

x

Variable Time Constant

x

x

Data Logging / Downloading

x

Review Data

x

Printer Output

x

x

NIST Calibration Certificate

x

x