Vacuum oven
For use in the degassing
process of the binder material that has been removed from the Pressure
Aging Vessel in accordance with AASHTO PP1-98. Immediately following the
degassing process, the material can then be tested in the Bending Beam
Rheometer, the Dynamic Shear Rheometer or the direct Tension device.
Degassing of the material prior to these tests insures that the material
does not contain air bubbles. Entrapped air can compromise the integrity
of the binder material, thus causing false failures in the previously
mentioned test devices.
All the features you have come to expect from
thermolyne
- Powder coated heavy gauge steel exterior for longevity.
- Easy-to-clean stainless steel chamber interior for ease of use.
- Exclusive polycarbonate safety shield protects door glass.
- Silicone door gasket and positive-latch door maintain seal at all
vacuum levels for accurate results.
- Two removable aluminum shelves inluded standard with each unit.
- Radiant warm wall heating provides uniformity and preserves working
chamber space.
- 3" glass wool insulation prevents heat loss from working chamber.
- Digital P.I.B. temperature controller provides excellent temperature
control for consistent results.
- Top mounted independent evacuation and venting vacuum fittings are
unique from all other models which feature front-mounted three-way valve
for evacuation, venting, and purging of inert gasses with vacuum
fittings.
- Vacuum Fittings Require 1/2" I.D. Tubing.
- Vacuum levels are displayed on gauges in inches of mercury.
- All controls conveniently located on side mounted panel for easy
operation.
- Maximum temperature 220 deg. C.
- Two-year warranty.
CAT.
NO. |
DESCRIPTION |
3606PAV |
- Chamber dimensions: 8W x 8H inches (20 x 20 cm)
- Overall dimensions: 17W x 17.375H x 16D inches (43 x 44
x 41 cm)
- Weight: 57 lbs (26 kg)
- Volts: 120
- Amps: 5.0
- Watts: 600
- Temp. display: digital
|
3606-1PAV |
- Chamber dimensions: 8W x 8H inches (20 x 20 cm)
- Overall dimensions: 17W x 17.375H x 16D inches (43 x 44
x 41 cm)
- Weight: 57 lbs (26 kg)
- Volts: 240
- Amps: 2.5
- Watts: 600
- Temp. display: digital
| |