UV/Visible  spectrophotometer ]

UV/Visible spectrophotometer
uv-visible_spectrophotometer.jpg (10829 octets)Model 6500
  • 5 modes of operation
    1. Photometrics
    2. Spectrum scanning
    3. Multi-wavelength
    4. Kinetics
    5. Quantitation
  • Standard with 8-cell motorized cell changer
  • Large housing fits wide variety of accessories
  • Versatile method and spectra storage
  • 1.8nm bandwidth
  • Wide range of operation
    • 320-1100nm (6500)
    • 190-1100nm (6505)
  • UV-lamp save option

The 6500 Visible and 6505 UV/Visible high performance spectrophotometers feature photometric, kinetic, spectrum scanning, multi-wavelength, and quantitation capabilities. High quality split-beam optics reduce stray light and enhance overall reliability by minimizing the number of optical elements.

The units operate through a graphical user interface with a mouse, keypad and a VGA back lit monochrome LCD for user-friendly interactive control. Data can be printed on an optional internal printer or a desktop printer and can be downloaded to PC through the bidirectional RS232. Results can be downloaded by a single touch of the print key. The internal memory and data card can store methods and results for recall and allow unlimited memory capacity. In addition, an automatic results log allows readings to be stored or printed at user set time intervals.

Photometrics

  • For routine measurements of % Transmittance, Absorbance, and Concentration
  • Selectable units: ppb, ppm, µg/l, mg/l, g/l, M, %, or blank
  • Large dual display of wavelength and photometric reading

Spectrum Scanning

The 6500 and 6505 have full scanning capabilities with:

  • 4 scan intervals: 0.2nm, 1nm, 5nm, 10nm
  • Scan speeds to 1200nm/minute
  • Instant display of spectrum scan
  • Auto re-scale capability
  • Hard copy printouts of settings, scan, statistics, and G.L.P. compliant information
  • Post scan analysis including peak and valley detection, area under curve, and addition/subtration
  • Ability to repeat and/or print scan at user set intervals
  • Baseline correction

Multi-wavelength

  • Simultaneous reading and display of up to 4 wavelengths
  • Readings displayed in % Transmittance, Absorbance, or Concentration
  • Selection of primary and secondary wavelengths
  • Selectable calculation displayed instantly
  • Calibration performed via single touch of the calibration key
  • Hard copy printouts of settings, calculations and G.L.P. compliant information

Kinetics

  • % Transmittance or Absorbance value versus time plotted
  • Adjustable lag and run time
  • Run can be set to start at a user set level of photometric value
  • Graphical display of data
  • Auto re-scale capability
  • Post run analysis including line of best fit, initial value, sloope, and concentration calculation
  • Hard copy printouts of settings, graph and statistical information
  • Ability to perform runs on 4 cells simultaneously
  • Temperature control accessories available

Quantitation

Samples are measured at a single wavelength and Concentration calculated from Absorbance or % Transmittance using a calibration curve constructed from standards.

  • Selectable number of calibration points to be performed up to 20
  • Up to 5 duplicate readings on each standard
  • Auto calibration at start of sequence
  • 8 curve fits from which to choose
  • Auto re-scale capability
  • Hard copy printouts of curve, statistical information and G.L.P. compliant information

Accessories

Wide ranges of accessories are available to enhance the application potential of the 6500 series Spectrophotometers. The accessories are easy to install and are easily controlled from keypad.

630-005 Universal Cell Holder: Holds cuvettes with 20 to 100mm pathlengths.
646-001 Universal Test Tube Holder: Holds test tubes between 12 and 24mm diameters.
642-001 Sipper Pump: Automated, accurate handling of small volume samples. Allows greater repeatability by use of the same cell. Offers selectable one or two stage sample transfer for optional air-gap after sample read. Once read, the sample can be flushed to waste or returned to the sample vial. Visible and UV/Visible Flow-Through Cells available.
643-031 Peltier Cell: A heated system comprised of a cell block and external power supply module. Temperature of 20 to 50°C at resolution of 0.1°C and a temperature measuring accuracy of ±0.5°C. The temperature is set by onboard software.
647-031 Peltier Sipper System: A combined version of the Sipper Pump and Peltier System.
645-001 Vacuum Pump: Uses a "pour in, suck out" cell. For use with a high throughput of sample.
648-001 Water Heated Cell Block: For use when a small flow of temperature controlled water is needed to maintain a temperature range of 4 to 50°C.
037-302 External Peltier Cooler: For use with 648-001
037-202 Water Circulator: For use with 648-001
641-001 Internal printer
Specifications
Model 6500 Model 6505
Wavelength
Range 320 to 1100 nm 190 to 1100 nm
Resolution 0.1 nm 0.1 nm
Accuracy ±1 nm ±1 nm
Bandwidth 1.8 nm 1.8 nm
Transmittance
Range 0 to 199.9% 0 to 199.9%
Resolution 0.1% 0.1%
Absorbance
Range -0.300 to 3.000A -0.300 to 3.000A
Resolution 0.001A 0.001A
Concentration
Range -300 to 9999 -300 to 9999
Resolution 0.001 / 0.01 / 0.1 / 1 0.001 / 0.01 / 0.1 / 1
Factor Range 0.000 to 9999.99 0.000 to 9999.99
Kinetics Lag Time 0 to 9999 seconds 0 to 9999 seconds
Kinetics Run Time 10 to 9999 secoonds 10 to 9999 seconds
Dwell Time 0 to 99 seconds 0 to 99 seconds
Photometric Linearity 0.005A @ 1.0A 0.005A @ 1.0A
Stray Light 0.05%T @ 340nm 0.05%T @ 340nm
Drift 0.001A per hour 0.001A per hour
Display Graphical LCD 12.6 x 9.5 in. Graphical LCD 12.6 c 9.5 in.
RS232 Bi-directional Bi-directional
Analog output Yes Yes
Visible Light Source Tungsten Halogen lamp Tungsten Halogen lamp
UV Light Source Deuterium lamp
Print/Save Auto Log Yes Yes
Input Power <150W <150W
Operating Temperature 15 to 30°C 15 to 30°C
Operating Humidity 0 to 90% RH 0 to 90% RH
Voltage/Frequency 117/240V / 50/60Hz 117/240V / 50/60Hz
Weight 33 lbs 33 lbs
CAT. NO. DESCRIPTION
650-001 Model 6500 Visible Spectrophotometer with 8 position multi-cell changer, pack of 100 x 3.5 ml disposable cuvettes. (240 volts 50 cycles)
650-031 Model 6500 Visible Spectrophotometer with 8 position multi-cell changer, pack of 100 x 3.5 ml disposable cuvettes. (117 volts 60 cyclles)
650-501 Model 6505 UV/Visible Spectrophotometer with 8 position multi-cell changer, pack of 100 x 3.5 ml disposable cuvettes (240 volts 50 cycles)
650-531 Model 6505 UV/Visible Spectrophotometer with 8 position multi-cell changer, pack of 100 x 3.5 ml disposable cuvettes. (117 volts 60 cycles)
641-002 Printer (Factory Fitted)
035-025 Visible Flow-through Cell 1.8 ml
035-045 Visible Flow-through Cell 80µl
035-044 UV Flow-through Cell 1.8 ml
035-047 UV Flow-through Cell 80µl
035-026 Pour in/Suck out Cell
035-124 Micro (50µl) Quartz cuvette
035-125 Micro (500µl) Quartz cuvette
035-127 Semi-micro (1ml) Quartz cuvette
035-129 Flow through (450µl) Quartz cuvette
035-131 Flow through (750µl) Quartz cuvette
035-088 Visible Calibbration Standards
035-091 UV/Visible Calibration Standards
640-133 Dust Cover