- [ 1100
Series
Visible Spectrophotometer
] - [ 2100
Series Visible & UV/Vis
Spectrophotometer ] - [ 800
Series Spectrophotometers
] -[ Smart
Spectrophoto- meter Model
2000 ] - [ Spectrophotometer
] - [ Spectrophotometer
Model
6305 ] -
[ UV/VIS
Spectro- photometer model V-530 ] - [
UV/Visible
spectrophotometer ] |
UV/Visible
spectrophotometer Model 6500
- 5 modes of operation
- Photometrics
- Spectrum scanning
- Multi-wavelength
- Kinetics
- Quantitation
- Standard with 8-cell motorized cell changer
- Large housing fits wide variety of accessories
- Versatile method and spectra storage
- 1.8nm bandwidth
- Wide range of operation
- 320-1100nm (6500)
- 190-1100nm (6505)
- UV-lamp save option
The 6500 Visible and 6505 UV/Visible high performance
spectrophotometers feature photometric, kinetic, spectrum scanning,
multi-wavelength, and quantitation capabilities. High quality split-beam
optics reduce stray light and enhance overall reliability by minimizing
the number of optical elements.
The units operate through a graphical user interface with a mouse,
keypad and a VGA back lit monochrome LCD for user-friendly interactive
control. Data can be printed on an optional internal printer or a desktop
printer and can be downloaded to PC through the bidirectional RS232.
Results can be downloaded by a single touch of the print key. The internal
memory and data card can store methods and results for recall and allow
unlimited memory capacity. In addition, an automatic results log allows
readings to be stored or printed at user set time intervals.
Photometrics
- For routine measurements of % Transmittance, Absorbance, and
Concentration
- Selectable units: ppb, ppm, µg/l, mg/l, g/l, M, %, or blank
- Large dual display of wavelength and photometric reading
Spectrum Scanning
The 6500 and 6505 have full scanning capabilities with:
- 4 scan intervals: 0.2nm, 1nm, 5nm, 10nm
- Scan speeds to 1200nm/minute
- Instant display of spectrum scan
- Auto re-scale capability
- Hard copy printouts of settings, scan, statistics, and G.L.P.
compliant information
- Post scan analysis including peak and valley detection, area under
curve, and addition/subtration
- Ability to repeat and/or print scan at user set intervals
- Baseline correction
Multi-wavelength
- Simultaneous reading and display of up to 4 wavelengths
- Readings displayed in % Transmittance, Absorbance, or Concentration
- Selection of primary and secondary wavelengths
- Selectable calculation displayed instantly
- Calibration performed via single touch of the calibration key
- Hard copy printouts of settings, calculations and G.L.P. compliant
information
Kinetics
- % Transmittance or Absorbance value versus time plotted
- Adjustable lag and run time
- Run can be set to start at a user set level of photometric value
- Graphical display of data
- Auto re-scale capability
- Post run analysis including line of best fit, initial value, sloope,
and concentration calculation
- Hard copy printouts of settings, graph and statistical information
- Ability to perform runs on 4 cells simultaneously
- Temperature control accessories available
Quantitation
Samples are measured at a single wavelength and Concentration
calculated from Absorbance or % Transmittance using a calibration curve
constructed from standards.
- Selectable number of calibration points to be performed up to 20
- Up to 5 duplicate readings on each standard
- Auto calibration at start of sequence
- 8 curve fits from which to choose
- Auto re-scale capability
- Hard copy printouts of curve, statistical information and G.L.P.
compliant information
Accessories
Wide ranges of accessories are available to enhance the application
potential of the 6500 series Spectrophotometers. The accessories are easy
to install and are easily controlled from keypad.
630-005 |
Universal Cell Holder: Holds
cuvettes with 20 to 100mm pathlengths. |
646-001 |
Universal Test Tube Holder: Holds
test tubes between 12 and 24mm diameters. |
642-001 |
Sipper Pump: Automated, accurate
handling of small volume samples. Allows greater repeatability by
use of the same cell. Offers selectable one or two stage sample
transfer for optional air-gap after sample read. Once read, the
sample can be flushed to waste or returned to the sample vial.
Visible and UV/Visible Flow-Through Cells available. |
643-031 |
Peltier Cell: A heated system
comprised of a cell block and external power supply module.
Temperature of 20 to 50°C at resolution of 0.1°C and a temperature
measuring accuracy of ±0.5°C. The temperature is set by onboard
software. |
647-031 |
Peltier Sipper System: A combined
version of the Sipper Pump and Peltier System. |
645-001 |
Vacuum Pump: Uses a "pour in, suck
out" cell. For use with a high throughput of sample. |
648-001 |
Water Heated Cell Block: For use
when a small flow of temperature controlled water is needed to
maintain a temperature range of 4 to 50°C. |
037-302 |
External Peltier Cooler: For use
with 648-001 |
037-202 |
Water Circulator: For use with
648-001 |
641-001 |
Internal
printer |
Specifications |
|
Model 6500 |
Model 6505 |
Wavelength |
Range |
320 to 1100 nm |
190 to 1100 nm |
Resolution |
0.1 nm |
0.1 nm |
Accuracy |
±1 nm |
±1 nm |
Bandwidth |
1.8 nm |
1.8 nm |
Transmittance |
Range |
0 to 199.9% |
0 to 199.9% |
Resolution |
0.1% |
0.1% |
Absorbance |
Range |
-0.300 to 3.000A |
-0.300 to 3.000A |
Resolution |
0.001A |
0.001A |
Concentration |
Range |
-300 to 9999 |
-300 to 9999 |
Resolution |
0.001 / 0.01 / 0.1 / 1 |
0.001 / 0.01 / 0.1 /
1 |
Factor
Range |
0.000 to 9999.99 |
0.000 to 9999.99 |
Kinetics Lag
Time |
0 to 9999 seconds |
0 to 9999 seconds |
Kinetics Run
Time |
10 to 9999 secoonds |
10 to 9999 seconds |
Dwell
Time |
0 to 99 seconds |
0 to 99 seconds |
Photometric
Linearity |
0.005A @ 1.0A |
0.005A @ 1.0A |
Stray
Light |
0.05%T @ 340nm |
0.05%T @ 340nm |
Drift |
0.001A per hour |
0.001A per hour |
Display |
Graphical LCD 12.6 x 9.5
in. |
Graphical LCD 12.6 c 9.5
in. |
RS232 |
Bi-directional |
Bi-directional |
Analog
output |
Yes |
Yes |
Visible Light
Source |
Tungsten Halogen lamp |
Tungsten Halogen
lamp |
UV Light
Source |
|
Deuterium lamp |
Print/Save Auto
Log |
Yes |
Yes |
Input
Power |
<150W |
<150W |
Operating
Temperature |
15 to 30°C |
15 to 30°C |
Operating
Humidity |
0 to 90% RH |
0 to 90% RH |
Voltage/Frequency |
117/240V / 50/60Hz |
117/240V / 50/60Hz |
Weight |
33 lbs |
33 lbs |
CAT.
NO. |
DESCRIPTION |
650-001 |
Model 6500 Visible
Spectrophotometer with 8 position multi-cell changer, pack of 100 x
3.5 ml disposable cuvettes. (240 volts 50 cycles) |
650-031 |
Model 6500 Visible
Spectrophotometer with 8 position multi-cell changer, pack of 100 x
3.5 ml disposable cuvettes. (117 volts 60 cyclles) |
650-501 |
Model 6505 UV/Visible
Spectrophotometer with 8 position multi-cell changer, pack of 100 x
3.5 ml disposable cuvettes (240 volts 50 cycles) |
650-531 |
Model 6505 UV/Visible
Spectrophotometer with 8 position multi-cell changer, pack of 100 x
3.5 ml disposable cuvettes. (117 volts 60 cycles) |
641-002 |
Printer (Factory
Fitted) |
035-025 |
Visible Flow-through Cell 1.8
ml |
035-045 |
Visible Flow-through Cell
80µl |
035-044 |
UV Flow-through Cell 1.8
ml |
035-047 |
UV Flow-through Cell
80µl |
035-026 |
Pour in/Suck out
Cell |
035-124 |
Micro (50µl) Quartz
cuvette |
035-125 |
Micro (500µl) Quartz
cuvette |
035-127 |
Semi-micro (1ml) Quartz
cuvette |
035-129 |
Flow through (450µl) Quartz
cuvette |
035-131 |
Flow through (750µl) Quartz
cuvette |
035-088 |
Visible Calibbration
Standards |
035-091 |
UV/Visible Calibration
Standards |
640-133 |
Dust
Cover | |