MAIN MENU

CATALOG INDEX
BY ALPHABETICAL
ORDER

CATALOG INDEX
BY DEPARTMENT

For more info:
JSi@jsits.com

- [ Datalogging Ultrasonic
Thickness Gauge
]

- [ Elcometer 456 ]
- [ Paint Inspection Gage ]
- [ Testex Tape &
Thickness Gauge
]

- [ Traceable Thickness
Standards

- [ Ultrasonic Micrometer ]
- [ Ultrasonic Thickness/Corrosion
Gauge
]

- [ Ultrasonic Thickness/Corrosion
Gauge
]

- [
Ultrasonic thickness
gauge
]
- [ Ultrasonic coating
thickness  gauge
]
- [ Wet Film Thickness
Measurement
]

Ultrasonic Thickness/Corrosion Gauge
The T-Mike ES uses the most advanced electronic and ultrasonic technology to offer the thickness gauge user many exceptional features.
Alarm
Allows rapid scanning of a test area, and illuminates green or red LEDs to alert the operator when thickness measurements are above or below a set value.

High-Speed Scan
Captures and displays the minimum thickness value measured while moving the transducer over the surface of the test piece.
Difference Function
Displays the positive or negative difference between the thickness measurement and present value.
Data Send
Allows continuous or on-command transmission of thickness readings vie the RS-232 port to a wide variety of portable data loggers or computers.
Automatic Probe Zero
Makes compensation for probe delay constants, probe temperature and probe wear fast and accurate.
These features combined with a sealed ergonomic metal case, quick change NiCad or Alkaline batteries, and unsurpassed accuracy make the T-Mike ES unequalled in performance and value.

Specifications:

Power Supply

  • Battery : 4 Alkaline or Ni-Cad batteries, interchangeable and easy to access
  • Continuous Operating Time : Approximately 80 hours continuous operating time with backlight. Typical operation 300 hours

Operation

  • Measuring Range : Typically 0.040 to 9.999 inches (depending on transducer and material measured)
  • Measuring Resolution : ±0.001 in. or 0.01 mm
  • Sound Velocity Range : From less than 0.999 inches per microsecond
  • Allowable Surface Temperature Range : 0°F to 330°F (-18°C to 150°C). High temperature probes available
  • Scan Mode : Allows operator to scan an area and display minimum thickness found
  • Alarm : The red LED lights to flag user when a reading falls below set target range; green LED lights to indicate an acceptable reading
  • Send : Allows operator to transmit current thickness value over RS-232 port
  • Diff Function : Indicates a plus (+) or minus (-) of a set thickness value.

Transducer

  • Desciption : 5 mHz, 0.25 in. diameter included
  • Configuration : Dual-element ultrasonic probe
  • Cable : 4-foot, environment protected
  • Unit Size :
    • 3.5 in. wide
    • 6.25 in. long
    • 1.5 in. deep
  • Weight : 20 oz
  • Keyboard : Hermetically sealed numeric touchpad
  • Data Transmission : Serial RS 232 bi-directional (1200/300 selectable baud rate)

Power Supply

  • Battery : 5 AA batteries, Alkaline, NiCad batteries, optional 110V or 220VAC
  • Continuous Operating Time : 16 hours
CAT. NO. DESCRIPTION
ST15200-00......... T-Mike ES with RS 232 Data port and dual element transducer
ST20065-00......... Optional High Resolution (Exxon spec.) Flex Probe