- [ 8
Eight Channel Temperature Logger -
SmartReader
8 ] - [ Data
Logger & Software Packages ] - [
Display
STARLOGGER Model 6004-2
] - [ Eight-Channel
Tempe- rature Info Logger - SmartReader Plus 8
] - [ Electric
Current and Temperature Info
Logger -
SmartReader Plus 3 ] - [ Electric Current and
Temperature
Logger - SmartReader 3
] - [ Hygro-Thermometer
Anemometer/Data
Logger ] - [ MACRO Data Logger
Model
7000 ] - [ MACRO Tester
model 7805A ] - [ Memory Card STAR
LOGGER
Model 6004-3 ] - [ Multi-channel
Thermo- couple
Info Logger - SmartReader 6 ] -
[ Multi-channel
Thermo- couple Info Logger -
SmartReader
Plus 6 ] - [ Pressure,
Temperature and RH Info Logger -
SmartReader
4 ] - [ Pressure,
Temperature, and RH Info Logger -
SmartReader
Plus 4 ] - [ Process Signal Info
Logger -
SmartReader Plus 7 ] - [ Process Signal Logger
- SmartReader
7 ] - [ Pulse Info Logger -
SmartReader
Plus 9 ] - [ Pulse Logger - Smart-
Reader 9
] - [ RF Remote
Site Monitoring Products
] - [ Rugged MS-DOS
5.0 Hand-Held
PC ] - [ Standard
STARLOGGER Model 6004-1
] - [ Temperature
and Rela- tive Humidity Logger -
SmartReader
2 ] - [ Temperature and
Rela- tive
Humidity Logger - SmartReader Plus 2
] - [ Temperature Info
Logger -
SmartReader Plus 1 ] - [ Temperature Logger
- SmartReader
1 ] - [ Thermocouple
Info Logger
- SmartReader Plus 5 ] - [ Thermocouple Logger
- SmartReader
5 ] |
Temperature and Relative
Humidity Info Logger - SmartReader Plus 2
Smart Reader Plus model 2 is a
self-contained data logger that is able to record both temperature
and relative humidity-right out the box. The on-board RH sensor is
temperature compensated permitting reliable, worry-free RH readings.
For remote sensing, simply attach an external temperature or
temperature /RH probe. |
|
Applications :
Monitoring the transportation or storage of
perishable and pharmaceutical goods; tracking of "air quality".
Accessories : ACR EH-020A Relative
Humidity/Temperature Probe; ACR ET Series of Thermistor Temperature
Probes; any NTC thermistor probe; replacement ACR RH-002 RH
sensor.
Specifications :
- No. of Channels : Four. (One for
internal temperature sensor, one for the internal RH sensor and the
remaining two channels are reserved for optional remote sensing of
temperature, relative humidity, or resistance)
- Relative Humidity Sensor : Capacitive
thin polymer film.
- Method of Operation : Changes in
relative humidity cause the capacitance of the sensor to vary.
SmartReader 2 Plus measures this value and converts the readings to a
percentage of RH. The RH reading is the temperature-compensated by a
smultaneously-taken temperature reading from the RH sensor's copanion
thermistor.
- Range : 0 to 100%
(non-condensing).
- Accuracy : +/-3% RH from 10 to 90%
(-20 to 40°C, -4 to 104°F).
- Resolution : Better than 0.04% between
25 & 60% RH at 25°C (77°F)
- Response Time : Adequate ventilation
reduces the response time which is approximately 5 minutes in still
air.
- Environmental Conditions : Like all
relative sensors, when exposed to contaminants and/or extreme
environmental conditions, accuracy degradation could result. For maximum
long-term stability, sensor should not be exposed or subjected to
organic solvents, corrosive agents (strong acids, SO2, H2SO4, Cl2, HCl,
H2S, etc.), and strong bases (compounds with pH greater than 7). Dust
settling on the sensor surface will not affect sensor performance except
possibly to decrease the speed of response. For more information on the
RH sensor's tolerance to chemicals, see ACR Accessories Catalog under
Relative Humidity.
Common Specifications :
- Size : 107 x 74 x 22 mm (4.2" x 2.9" x
0.9")
- Weight : 110 grams (3.75
ounces)
- Case Material : Noryl Plastic
- Operating Limits : -45°C to 70°C
(-50°F to 160°F) and 0 to 95% Relative Humidity (non-condensing)
- Clock-Accuracy : +/-2 seconds per day
plus one sampling interval
- Battery : 3.6 volt Lithium, 1
Amp-Hour
- Power Consumption : 5 to 10 microamps
(continuous)
- Battery Life : Ten years (Factory
Replaceable)
- External Connector : Removable
screw-type terminal strip with Common (-) connection
- Memory Size : 21,500 readings
- Sampling Methods :
- Continuous (First-in, First-out)
- Stop when full (Fill-then-stop)
- Sampling Rates : User selectable rates
from 25 per second to every 8 hours. (BP-100 battery pack required for
sample rates less than 8 seconds)
- Resolution : 12 bits (1 part in
4096)
- PC Hardware Requirements : IBM PC or
100% compatible with: at least one free serial port;
- Software Requirements : TrendReader
for Windows-Windows version 3.1 or later already running with at least
2MB of RAM memory and 2MB of hard drive disk space
- Product Approvals : Meets Part 15 for
Digital Devices of the Code of Federal Regulations of the Federal
Communications Commission (FCC). Meets Class A radiated and conducted
emission requirements of Section 2 of the Radio Interference Regulations
of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI
Immunity, EFT/Burst and Radiated Emmisions repectively for the Commision
of the European Communities (CE).
- Resistance to X-Rays : Tested for
protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38
inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested
for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object distance
5"
Internal Temperature Sensor (common on all
models):
- Type : Negative Temperature
Coefficient Thermistor.
10,000 ohms @ 25°C (77°F).
- Tolerance (sensor only) : +/-0.2°C,
over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to
158°F).
- Range : -40 to 70°C (-40 to
158°F)
- Resolution : 0.03°C (0.05°F) at 25°C
(77°F).
Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C
(158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C
(-13°F).
CAT.
NO. _ |
DESCRIPTION _ |
ACRSRP-002............. |
Temperature & Relative Logger
128K |
ACRTR-WIN-SRP.... |
TrendReader includes everything needed
to access information from any 12 bit SRP logger Windows
version |
ACRET-020A............ |
Remote RH & Temperature
Sensing |
ACRET-016............... |
General Purpose Temperature
Probe | |