MAIN MENU
CATALOG INDEX BY ALPHABETICAL ORDER
CATALOG
INDEX BY DEPARTMENT
For more info: JSi@jsits.com
- [ 8
Eight Channel Temperature Logger -
SmartReader
8 ] - [ Data
Logger & Software Packages ] - [
Display
STARLOGGER Model 6004-2
] - [ Eight-Channel
Tempe- rature Info Logger - SmartReader Plus 8
] - [ Electric
Current and Temperature Info
Logger -
SmartReader Plus 3 ] - [ Electric Current and
Temperature
Logger - SmartReader 3
] - [ Hygro-Thermometer
Anemometer/Data
Logger ] - [ MACRO Data Logger
Model
7000 ] - [ MACRO Tester
model 7805A ] - [ Memory Card STAR
LOGGER
Model 6004-3 ] - [ Multi-channel
Thermo- couple
Info Logger - SmartReader 6 ] -
[ Multi-channel
Thermo- couple Info Logger -
SmartReader
Plus 6 ] - [ Pressure,
Temperature and RH Info Logger -
SmartReader
4 ] - [ Pressure,
Temperature, and RH Info Logger -
SmartReader
Plus 4 ] - [ Process Signal Info
Logger -
SmartReader Plus 7 ] - [ Process Signal Logger
- SmartReader
7 ] - [ Pulse Info Logger -
SmartReader
Plus 9 ] - [ Pulse Logger - Smart-
Reader 9
] - [ RF Remote
Site Monitoring Products
] - [ Rugged MS-DOS
5.0 Hand-Held
PC ] - [ Standard
STARLOGGER Model 6004-1
] - [ Temperature
and Rela- tive Humidity Logger -
SmartReader
2 ] - [ Temperature and
Rela- tive
Humidity Logger - SmartReader Plus 2
] - [ Temperature Info
Logger -
SmartReader Plus 1 ] - [ Temperature Logger
- SmartReader
1 ] - [ Thermocouple
Info Logger
- SmartReader Plus 5 ] - [ Thermocouple Logger
- SmartReader
5 ] |
Temperature Logger -
SmartReader 1
Smart Reader 1 is an easy-to-use data
logger designed for effortless temperature recording. Quick and
simple to set up, it works right ou of the box, logging temperature
readings from its internal precision-calibrated on-board sensor. For
added versatility you can also use an optional remote temperature
probe. |
|
Applications :
Checking out comfort complaints, settlings disputes,
balancing heating and cooling systems, troubleshooting Energy Management
controls, and monitoring the transportation and storage of
temperature-sensitive goods.
Accessories : ET Thermistor temperature
probes. SmartReader 1 is compatible with any NTC thermistor
probe.
Specifications :
- Size : 107 x 74 x 22 mm (4.2" x 2.9" x
0.9")
- Weight : 110 grams (5 ounces)
- Case Material : Noryl Plastic
- Operating Limits : -45°C to 70°C
(-50°F to 160°F) and 0 to 95% Relative Humidity (non-condensing)
- Clock-Accuracy : +/-8 seconds per day
plus one sampling interval
- Battery : 3.6 volt Lithium, 1
Amp-Hour
- Power Consumption : 5 to 10 microamps
(continuous)
- Battery Life : Ten years (Factory
Replaceable)
- External Connector : Removable
screw-type terminal strip with Common (-) connection
- Memory Size : 32,768 readings
- Sampling Methods :
- Continuous (First-in, First-out)
- Stop when full (Fill-then-stop)
- Sampling Rates : User selectable rates
from every 8 seconds to once a week
- Resolution : 8 bits (1 part in
256)
- PC Hardware Requirements : IBM PC or
100% compatible with: at least one serial port; an IBM CGS, EGA, HGA,
VGA, or other adapter capable of emulating thses standards
- Software Requirements :
- TrendReader for DOS-MS DOS version 3.0 or later and
at least 512 K of RA memory. TrendReader for DOS supports a wide range
of printers and plotters.
- TrendReader for Windows-Windos version 3.1 or later
already running with at least 2MB of RAM memory and 2MB of hard drive
disk space
- Product Approvals : Meets Class A
radiated and conducted emission requirements of Section 2 of the Radio
Interference Regulations of Communications Canada and of Part 15 for
Digital Devices of the Code of Federal Regulations of the Federal
Communications Commission (FCC).
- Resistance to X-Rays : Tested for
protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38
inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested
for protection against Gamma Ray (equivalent to 0.1337 - 1.38 mega
volts) IR 192 - 28 curies @ 30 second exposure source to object distance
5"
Internal Temperature Sensor (common on all
models):
- Type : Negative Temperature
Coefficient Thermistor
- R25 Value : 10,000 ohms
- Tolerance (sensor only) : +/-0.2°C,
over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to
158°F).
- Range : -40 to 70°C (-40 to
158°F)
- Resolution : 0.4°C (0.7°F). Better
than 1°C (1.8°F) between -25°C (-13°F) and 70°C (158°F). Better than
2.0°C (3.6°F) between -40°C (-40°F) and -25°C (-13°F).
CAT. NO. _ |
DESCRIPTION _ |
ACRSR001-0....... |
Temperature Logger |
ACRET016-0....... |
External temperature probe. |
ACRTRSFW-0.... |
TrendReader software with IC-100
cable | |