- [ 8
Eight Channel Temperature Logger -
SmartReader
8 ] - [ Data
Logger & Software Packages ] - [
Display
STARLOGGER Model 6004-2
] - [ Eight-Channel
Tempe- rature Info Logger - SmartReader Plus 8
] - [ Electric
Current and Temperature Info
Logger -
SmartReader Plus 3 ] - [ Electric Current and
Temperature
Logger - SmartReader 3
] - [ Hygro-Thermometer
Anemometer/Data
Logger ] - [ MACRO Data Logger
Model
7000 ] - [ MACRO Tester
model 7805A ] - [ Memory Card STAR
LOGGER
Model 6004-3 ] - [ Multi-channel
Thermo- couple
Info Logger - SmartReader 6 ] -
[ Multi-channel
Thermo- couple Info Logger -
SmartReader
Plus 6 ] - [ Pressure,
Temperature and RH Info Logger -
SmartReader
4 ] - [ Pressure,
Temperature, and RH Info Logger -
SmartReader
Plus 4 ] - [ Process Signal Info
Logger -
SmartReader Plus 7 ] - [ Process Signal Logger
- SmartReader
7 ] - [ Pulse Info Logger -
SmartReader
Plus 9 ] - [ Pulse Logger - Smart-
Reader 9
] - [ RF Remote
Site Monitoring Products
] - [ Rugged MS-DOS
5.0 Hand-Held
PC ] - [ Standard
STARLOGGER Model 6004-1
] - [ Temperature
and Rela- tive Humidity Logger -
SmartReader
2 ] - [ Temperature and
Rela- tive
Humidity Logger - SmartReader Plus 2
] - [ Temperature Info
Logger -
SmartReader Plus 1 ] - [ Temperature Logger
- SmartReader
1 ] - [ Thermocouple
Info Logger
- SmartReader Plus 5 ] - [ Thermocouple Logger
- SmartReader
5 ] |
Temperature Info Logger -
SmartReader Plus 1
Smart Reader Plus model 1 is a data
logger specifically designed for easy monitoring and recording of
temperature. With one internal ambient temperature channel and an
input for optional remote temperature or contact closure sensing.
SmartReader Plus model 1 is ideal for quick and accurate temperature
recordings in a variety of diverse applications. |
|
Applications :
Food process verificastion; pharmaceutical
storage; laboratories; equipment runtime.
Accessories : ACR ET Series of Thermistor
Temperature Probes; any NTC thermistor probe.
Specifications :
- No. of Channels : Two. (One for the
internal temperature sensor and one for remote sensing of temperature,
switch status or resistance)
- Size : 107 x 74 x 22 mm (4.2" x 2.9" x
0.9")
- Weight : 110 grams (3.75
ounces)
- Case Material : Noryl Plastic
- Operating Limits : -45°C to 70°C
(-50°F to 160°F) and 0 to 95% Relative Humidity (non-condensing)
- Clock-Accuracy : +/-2 seconds per day
plus one sampling interval
- Battery : 3.6 volt Lithium, 1
Amp-Hour
- Power Consumption : 5 to 10 microamps
(continuous)
- Battery Life : Ten years (Factory
Replaceable)
- External Connector : Removable
screw-type terminal strip with Common (-) connection
- Memory Size : 21,500 readings
- Sampling Methods :
- Continuous (First-in, First-out)
- Stop when full (Fill-then-stop)
- Sampling Rates : User selectable rates
from 25 per second to every 8 hours. (BP-100 battery pack required for
sample rates less than 8 seconds)
- Resolution : 12 bits (1 part in
4096)
- PC Hardware Requirements : IBM PC or
100% compatible with: at least one free serial port;
- Software Requirements : TrendReader
for Windows-Windows version 3.1 or later already running with at least
2MB of RAM memory and 2MB of hard drive disk space
- Product Approvals : Meets Part 15 for
Digital Devices of the Code of Federal Regulations of the Federal
Communications Commission (FCC). Meets Class A radiated and conducted
emission requirements of Section 2 of the Radio Interference Regulations
of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI
Immunity, EFT/Burst and Radiated Emmisions repectively for the Commision
of the European Communities (CE).
- Resistance to X-Rays : Tested for
protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38
inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested
for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object distance
5"
Internal Temperature Sensor (common on all
models):
- Type : Negative Temperature
Coefficient Thermistor.
10,000 ohms @ 25°C (77°F).
- Tolerance (sensor only) : +/-0.2°C,
over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to
158°F).
- Range : -40 to 70°C (-40 to
158°F)
- Resolution : 0.03°C (0.05°F) at 25°C
(77°F).
Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C
(158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C
(-13°F).
CAT.
NO. _ |
DESCRIPTION _ |
ACRSRP-001............. |
Temperature Logger 128K |
ACRTR-WIN-SRP.... |
TrendReader includes everything needed
to access information from any 12 bit SRP logger Windows
version |
ACRET-016............... |
Generator Purpose Temperature
Probe |
ACRET-004............... |
Low Temperature Penetration
Probe |
ACRET-081............... |
High Temperature
Probe | |