MAIN MENU
CATALOG INDEX BY ALPHABETICAL ORDER
CATALOG
INDEX BY DEPARTMENT
For more info: JSi@jsits.com
- [ 4
& 3 Gas Monitors - Low cost &
basic ] - [
450
Photoionization Detector ] - [ AIM
000 Series and 250 Series Gas Detectors
] - [ AIM
600 Millennium Compact Gas
Monitor ] - [ AIM
915 series "stand alone" gas detector ] - [
CO Alarm
- residential ] -
[ Pocket-size
Portable Radiation Alert,
Monitor
] - [ Gas
Data LMSxi
] - [ Q-Check
CO2 and CO Meter ] - [ Shirtpocket Size
Ozone
Sensor ] - [ Simple,
Inexpensive Ozone Monitor ] -
[ Single
Gas Portable Monitors ] - [ Testo 300 ] - [
Testo 400
] - [ Testo
450 ] - [ TIF5GA
Automovite exhaust gas
detector ] - [ TIF8800A
Combus- tible
Gas Detector ] - [ VOC Gas
sensors ] - [ VOC Monitor ] -
[ Yes-205-5 Five
Channel IAQ Datalogger ] |
|
Multifunction
instrument The Testo
400
Testo New Professional Class - The reference measuring
instruments
testo 400 is the multi-function instrument designed to simplify the
measuring tasks of professionals and tradesmen.
The testo 400 measures and
records:
- Temperature with accuracies to <0.1 °C/°F. Probes have
calibration for adjustment capabilities.
- Humidity/Dew point, complete Mollier diagram values.
- CO and CO2 with ambient levels
- pressure, differential pressure and also absolute pressure
- Velocity measurements using thermal, vane and pitot tube probes.
- It also calculates volumne flow, max, min and values mention of
ASHRAE Speck's
- The mV/mA measurement input easily checks transducers outputs.
- Logs data with date, time and location over long time periods using
the logger function in the measuring instrument.
Equipped for the future The
following functions are upgradable (available in mid
1998):
- The measuring instrument guides you through volume flow calculations
and calculates, for example, immerson depths, number of measuring points
etc.
- Calculates measuring inaccuracies on location
Description
The precision multifunction instrument and datalogger measures
temperature, CO, CO2, rpm, mV and mA, % RH, pressure and velocity.
- Rapid measurement with accurate temperature probes.
The
instrument can extrapolate the final value for faster response times.
- Highest precision due to system calibration (measuring instrument +
probe)
Calibration data is saved in the probe.
- Calculates all of the physical humidity parameters in the Mollier
diagram:
- relativ humidity (% RH) - dew point, pressure dew
point (tp, tdp) - absolute humidity (g/m3) - humidity levels (g/kg
pressure-compensated) - humidity, wet temperature °C and °F -
water vapour partial pressure in mbar/hPa - Enthalpy kcal/kg
- Humidity probes for every application, from remaining humidity to
high humidity levels
- Indent guaranteed long-term stability
- Highest accuarcy ± 1 %
- All of the conventional types of averaging are available
- Volume flow measurement (cfm, m3/min, l/s)
- Duct dimensions in the various measurement locations can be saved in
the instrument. When the measurement location is called up the saved
dimensions can be used to measure cfm.
- Measures the barometric pressure (absolute pressure) as a reference
value or for the correct Pitot tube measurement.
- Measures turbulence levels.
Features:
- Measuring instrument and display are integrated in the
probe
- Very practical one-hand operation
- No awkward cable connections
- Robust, waterproof design, can be wiped clean
Technical data
Temperature |
Pt100 |
Measuring Range: |
-200 to +800 ºC (-328 to +1472 ºF) |
System Accuracy: |
up to ± 0.1°C / ± 0.1°F (Class A, B) |
Resolution: |
0.01°C (0.01°F) |
NiCr-Ni |
Measuring Range: |
-200 to +1,370°C (-328 to +2498°F) |
PtRh-Pt |
Measuring Range: |
0 to +1,760°C (32 to +3200°F) |
FeCu-Ni |
Measuring Range: |
-200 to +1,000°C (-328 to +1832°F) |
NTC |
Measuring Range: |
-50 to +150°C (-58 to +302°F) |
System Accuracy: |
up to 0.4°C (0.4°F) |
Humidity |
Temperature: |
-30°C to +180°C (-22°F to +356°F) |
Measuring Range: |
0 to 100% RH |
System Accuracy: |
up to ± 1.0 % RH |
Pressure |
Measuring Range: |
± 0.1 bar ± 0.01bar 2 bar 10 bar 30 bar |
Velocity |
Vane Measuring Range: |
0 to 60 m/s (0 to 12,000 fpm) |
Thermal Measuring Range: |
0 to 20 m/s (0 to 4,000 fpm) |
Pitot tube measuring range: |
0 to 10 mbar / 100 mbar 0 to 40 m/s / 100 m/s (0 to 8,000 /
20,000 fpm) |
Volume flow in l/s, m3/min, m3/h |
Measuring Range: |
360.000 cfm (max. calculated at 1 m2, 20,000
fpm values) |
CO |
Measuring Range: |
0 to 500 ppm |
Accuracy: |
± 5 ppm |
CO2 |
Measuring Range: |
0 to 10,000 ppm 0 to 1 vol. % |
Accuracy: |
± 5% of m.v. or 100 ppm |
rpm |
Measuring Range: |
0.333 to 333 Hz 20 to 20,000 rpm |
Accuracy: |
± 1 digit |
Current/voltage |
Measuring Range: |
0 to 20 mA / 4 to 20 mA 0 to ± 10 V / 0 to ± 1 V |
General technical data |
Memory space |
Basic version: |
15 kB, cooresponds to approx. 7,500 meas. values |
Optional version: |
1 MB, corresponds to approx. 500,000 meas. values |
Power supply: alternatively: |
battery / rechargeable battery 8 V mains unit |
Rechargeable battery lifetime: |
18 h (continous oper. w. 2 thermocouple probes) |
Operation temperature: |
0 to +50 °C (32 to +122°F) short-term 0 to +60°C (32 to
+140°F) |
Storage/transport temperature: |
-25 to +60°C (-13 to +140°F) |
Weight: |
650 g (incl. rech. battery) 1 lbs. 7 ozs. |
Other factores: |
- Automatic recognition of all connected probes - RS 232
interface for data management |
Warranty: |
Instrument: 3 years Probe: 1 year |
|
|
There are a lot of probe available including immersion/penetration,
surface, air and flue gas probe. For more information on these probes,
please contact us.
CAT. NO. |
DESCRIPTION |
TE400-000......... |
testo 400 measurements on air cand. and
ventil. systems Convenient and user-friendly. With volume
flow.
- testo 400, 2 channel multi-function measuring
instrument with batteries and Li cell
- Bendable vane probe (plug-in), Ø 2" ideal for
duct exits
- Combined vane/temperature probes (plug-in), for
air conditioning/ventillation ducts
- Telescope for plug-in vane probes, max. 3ft
long
- Humidity/temperature probe for measurements in
air conditioning systems (for measuring all physical parameters in
the Mollier diagram)
- Surface temperature probes for super-quick
temperature measurement
- Comfort level probe for measuring degree of
turbulence, incl. stand
- NIST calibration certificate, calibration range
freely selectable from 20 to 10 000 fpm
| |