Standard STARLOGGER Model
6004-1
The Standard STARLOGGER is the first in a familly of
data loggers designed to meet your exacting requirements by offering
not only an extended signal capacity and range but also easier
programmability. |
|
The latest development in this range of dataloggers, the STARLOGGERs
offer 12 input channels, two high speed serial input/output busses and two
outputs. They also provide two power sources for external instruments..
The range of scan rates extends from 125 milliseconds to 5 minutes.
Designed for trouble-free operation in a wide range of data logging
applications, the STARLOGGER is upwardly compatible with the STARLOG
Portable Data Logger. It readily replaces a PDL and also offers increased
performance.
All STARLOGGERs feature eight (10 bit) analog channels, four (16 bit)
counter/frequency channels, and sisten (16 bit) STARBUS serial I/O
channels. Memory is a large 128K capacity CMOS RAM, enough storage for
many mounths of recording. STARLOGGERs are completely portable, containing
an internal battery supply for one year of normal operation. Like all
UNIDATA loggers, it is fully programmable using the STARLOG programming
language.
The STARLOGGER communicates using standard asynchronous RS-232 serial
communication standards which allow it to communicate with an IBM PC or
compatible computer using a standard cable.
STARLOGGER Specifications
- Analog Input : 8 channel, 10-bit
resolution, single ended, unipolar, plus temperature and battery
voltage. Voltage input in two ranges, programmable : 0 to 2.550 volts,
2.5 mV resolution, 0 to 255 mV, 250 µV resolution
- Input Impedance : >1M ohms
- Load Impedance : For signals <500
mV: >1M ohm For signals <500mV : 10 Kohms
- Source Drive Impedance : <10
Kohms
- Counter Input : 4 channel, 16-bit
resolution, 20kHz, potential free or 5-12V pulse
- STARBUS : 2 high speed serial lines
with 8 channels each, 16-bit, bi-directional, synchronous data &
clock
- SDI-12 : 1200 bps, instrument channel
(Models 6004-2 and 6004-3 only)
- Controls : 1 open collector, 1
CMOS
- Available Voltages : 5 V, 100mA
regulated scan synchronised; 1mA unregulated continuous
- Scan Rate : 0.125 second to 5 minutes,
programmable
- Log Interval : 0.125 second to 1 week,
programmable
- Storage Memory : 128 K bytes CMOS
RAM
- Time Clock : Crystal regulated, ±10
seconds per month
- Battery : 10Ah Alkaline pack
(Rechargeable NiCard available)
- Memory Back-up : 1/2 AA 3.4 V Litium
(optional)
- Processor : 8 bit, 80C31 micro
controller, 14.7456 MHz
- Computer I/O : RS-232, 300-38400
bps
- Operating Temperature : -20°C to 60°C,
not affected by humidity
- Enclosure : High impact PVC,
IP54
- Size/Weight : 211mm x 108mm x 81mm,
800g (excl. battery)
- Display : 32 ASCII character LCD
(Models 6004-2 and 6004-3)
CAT.
NO.
UN6004-110........
UN6004-130........ |
DESCRIPTION
6004B STARLOGGER with 128K and
6910A Alkaline Battery Pack 6004B STARLOGGER
with 128K and 6910B NiCad Battery
Pack | |