CAT.
NO. |
DESCRIPTION |
LAM1911-000 |
Smart
Colorimeter, 120V, 60 Hz. |
LAM1911-EX2 |
Smart
Colorimeter, 220V, 50 Hz. |
LAM1912-300 |
Smartlink
Program & computer interface cable 3.5 inches |
3641-SC |
- Test Factor: Aluminum
- Range PPM: 0-0.3
- Test Method (# of Reagents): Eriochrome Cyanine R
(4)
- # of Tests: 50
- Case type: C
|
3659-01-SC |
- Test Factor: Ammonia Nigrogen
- Range PPM: 0-1.0
- Test Method (# of Reagents): Salicylate
(3)
- # of Tests: 25
- Case type: A
|
3642-SC |
- Test Factor: Ammonia Nitrogen
- Range PPM: 0-3.0
- Test Method (# of Reagents): Nesslerization
(2)
- # of Tests: 50
- Case type: A
|
3643-SC |
- Test Factor: Bromine
- Range PPM: 0-1.0
- Test Method (# of Reagents): DPD Tablets
(2)
- # of Tests: 100
- Case type: A
|
3643-SC |
- Test Factor: Chlorine
- Range PPM: 0-4.0
- Test Method (# of Reagents): DPD Tablets
(2)
- # of Tests: 100
- Case type: A
|
3643-SC |
- Test Factor: Iodine
- Range PPM: 0-16
- Test Method (# of Reagents): DPD Tablets
(2)
- # of Tests: 100
- Case type: A
|
3644-SC |
- Test Factor: Chlorine Dioxide
- Range PPM: 0-7.0
- Test Method (# of Reagents): DPD Tablet/Glycine
(2)
- # of Tests: 50
- Case type: A
|
3645-SC |
- Test Factor: Chromium, Hexavalent
- Range PPM: 0-1.0
- Test Method (# of Reagents): Diphenlcarbazide
(1)
- # of Tests: 100
- Case type: C
|
3698-SC |
- Test Factor: Chromium, Total, Hexa- &
Trivalent
- Range PPM: 0-1.0
- Test Method (# of Reagents): Diphenylcarbazide
(1)
- # of Tests: 100
- Case type: D
|
5-3684-SC |
- Test Factor: COD, Low
- Range PPM: 5-150
- Test Method (# of Reagents): Digestion (mercury
free)
- # of Tests: 50
- Case type: D
|
5-0002-SC |
- Test Factor: COD, Low
- Range PPM: 5-150
- Test Method (# of Reagents): Digestion (contains
mercury)
- # of Tests: 50
- Case type: D
|
5-3685-SC |
- Test Factor: COD, Standard
- Range PPM: 20-900
- Test Method (# of Reagents): Digestion (mercury
free)
- # of Tests: 50
- Case type: D
|
5-0003-SC |
- Test Factor: COD, Standard
- Range PPM: 20-900
- Test Method (# of Reagents): Digestion (contain
mercury)
- # of Tests: 50
- Case type: D
|
5-0007-SC |
- Test Factor: COD, High
- Range PPM: 100-4500
- Test Method (# of Reagents): Digestion
(mercury)
- # of Tests: 50
- Case type: D
|
3646-SC |
- Test Factor: Copper
- Range PPM: 0-5.0
- Test Method (# of Reagents):
Diethyldthiocarbamate (1)
- # of Tests: 100
- Case type: A
|
3640-SC |
- Test Factor: Copper
- Range PPM: 0-3.0
- Test Method (# of Reagents): Bicinchoninic Acid
(1)
- # of Tests: 50
- Case type: A
|
3660-SC |
- Test Factor: Cyanide
- Range PPM: 0-0.5
- Test Method (# of Reagents): Pyridine-Barbituric
Acid (5)
- # of Tests: 50
- Case type: C
|
3661-SC |
- Test Factor: Cyanuric Acide
- Range PPM: 5-200
- Test Method (# of Reagents): Melamine (1)
- # of Tests: 50
- Case type: C
|
3647-SC |
- Test Factor: Fluoride
- Range PPM: 0-2.0
- Test Method (# of Reagents): SPADNS (2)
- # of Tests: 50
- Case type: B
|
3656-SC |
- Test Factor: Hydrazine
- Range PPM: 0-1.0
- Test Method (# of Reagents):
P-dimethylaminobenzaldehyde (2)
- # of Tests: 50
- Case type: A
|
3662-SC |
- Test Factor: Hydrogen Peroxide
- Range PPM: 0-1.5
- Test Method (# of Reagents): DPD Tablets
(2)
- # of Tests: 100
- Case type: A
|
3648-SC |
- Test Factor: Iron
- Range PPM: 0-5.0
- Test Method (# of Reagents): Bipyridyl (2)
- # of Tests: 50
- Case type: A
|
3668-SC |
- Test Factor: Iron
- Range PPM: 0-6.0
- Test Method (# of Reagents): 1, 10 Phenanthroline
(2)
- # of Tests: 50
- Case type: A
|
3658-SC |
- Test Factor: Manganese (LR)
- Range PPM: 0-0.9
- Test Method (# of Reagents): PAN (3)
- # of Tests: 50
- Case type: B
|
3669-SC |
- Test Factor: Manganese (HR)
- Range PPM: 0-10.0
- Test Method (# of Reagents): Periodate (2)
- # of Tests: 50
- Case type: A
|
3699-01-SC |
- Test Factor: Molybdenum
- Range PPM: 0-30
- Test Method (# of Reagents): Thioglycolate
(3)
- # of Tests: 50
- Case type: B
|
3663-SC |
- Test Factor: Nickel
- Range PPM: 0-10.0
- Test Method (# of Reagents): Dimethylglyoxime
(6)
- # of Tests: 50
- Case type: D
|
3649-SC |
- Test Factor: Nitrate Nitrogen
- Range PPM: 0-3.0
- Test Method (# of Reagents): Cadmium Reduction
(2)
- # of Tests: 20
- Case type: A
|
3650-SC |
- Test Factor: Nitrite Nitrogen
- Range PPM: 0-0.7
- Test Method (# of Reagents):
Diazotization/Coupling (2)
- # of Tests: 20
- Case type: A
|
3688-SC |
- Test Factor: Oxygen, Dissolved
- Range PPM: 0-12.5
- Test Method (# of Reagents): Winkler Colorimetric
(3)
- # of Tests: 200
- Case type: A
|
3651-SC |
- Test Factor: Ozone
- Range PPM: 0-0.4
- Test Method (# of Reagents): Indigo Trisulfonate
(3)
- # of Tests: 100
- Case type: D
|
3700-SC |
- Test Factor: pH
- Range PPM: 5.0-9.6
- Test Method (# of Reagents): Colorimetric
(3)
- # of Tests: 100
- Case type: C
|
3652-SC |
- Test Factor: Phenols
- Range PPM: 0-6.0
- Test Method (# of Reagents): 4-Aminoantipyrine
(3)
- # of Tests: 50
- Case type: C
|
3655-SC |
- Test Factor: Phosphate (HR)
- Range PPM: 0-80.0
- Test Method (# of Reagents): Molybdovanadate
(1)
- # of Tests: 50
- Case type: A
|
3653-SC |
- Test Factor: Phosphate (LR)
- Range PPM: 0-3.0
- Test Method (# of Reagents): Ascorbic Acid
Reduction (2)
- # of Tests: 50
- Case type: A
|
3639-SC |
- Test Factor: Potassium
- Range PPM: 1.0-10.0
- Test Method (# of Reagents): Tetraphenylboron
(2)
- # of Tests: 100
- Case type: A
|
3664-SC |
- Test Factor: Silica (LR)
- Range PPM: 0-4.0
- Test Method (# of Reagents): Heteropoly Blue
(4)
- # of Tests: 100
- Case type: A
|
3687-SC |
- Test Factor: Silica (HR)
- Range PPM: 0-75
- Test Method (# of Reagents):
Silicomalybdate
- # of Tests: 50
- Case type: A
|
3665-SC |
- Test Factor: Sulfate
- Range PPM: 0-100
- Test Method (# of Reagents): Barium Chloride
(1)
- # of Tests: 100
- Case type: A
|
3654-SC |
- Test Factor: Sulfide
- Range PPM: 0-3.0
- Test Method (# of Reagents): Methylene Blue
(3)
- # of Tests: 50
- Case type: B
|
3666-SC |
- Test Factor: Tannin
- Range PPM: 0-10
- Test Method (# of Reagents):
Tungsto-Molybdophosphoric Acid (2)
- # of Tests: 50
- Case type: C
|
|
- Test Factor: Turbidity
- Range PPM: 0-400 FTU
- Test Method (# of Reagents):
Absorptimetric
- # of Tests: Unlimited
|
3667-SC |
- Test Factor: Zinc
- Range PPM: 0-3
- Test Method (# of Reagents): Zincon (6)
- # of Tests: 50
- Case type: D
|