MAIN
MENU
CATALOG INDEX BY ALPHABETICAL ORDER
CATALOG
INDEX BY DEPARTMENT
For more info: JSi@jsits.com
- [ LaMotte Deluxe
Turf Lab
] - [ Portable
Colorimeter ] - [ Single
Test Colorimeter ] - [ Smart Colorimeter
] |
Single Test
Colorimeters
The new 1200 Series of single test, direct reading colorimeters
incorporates design advances that enhance reliability, improve accuracy,
and simplify the calibration process, all in a portable, hand-held
package.
Single test colorimeters are available for the following test factors:
ammonia nitrogen, bromine, chlorine (free & total), chlorine dioxide,
copper, fluoride, iron, manganese, molybdenum, nitrate nitrogen, ozone,
phosphate and sulfate.
Features
- Designed with excessive exposure to moisture in mind, the 1200
colorimeters deliver trouble-free performance in the field and lab.
- The microprocessor enables the factory programmed calibrations to
optimally match non-linear curves.
- Simply insert the sample blank and press the zero key. No more
dialing in the zero.
- Flip-top lib over sample chamber prevents any stray light,
especially in the field, and avoids misplacing separate light caps.
- The large 3-1/2 digit display presents measurements in actual ppm
concentration, and indicates low battery warnings.
- An RS-232 port is provided to interface with a datalogger or
computer.
- The 1200 has been independently tested and has earned the European
CE Mark of compliance for electromagnetic compatibility and safety.
- An optional AC adapter is available to save battery when in the
laboratory.
Specifications
- Instrument type: single wavelength, direct-reading
colorimeter
- Readout: 3-1/2 digit LCD
- Photometric accuracy: ±0.001 absorbance unit
- Detector: Silicon photodiode
- Sample chamber: accepts 25mm diameter, flat-bottom,
capped test tubes (included)
- Light source: LED
- Interface: RS-232 serial interface
- Power: Alkaline 9 Volt DC battery, 3.5mm jack for
optional AC adapter
- Size (LxWxH): 15 x 8 x 5.5 cm (6 x 3-1/4 x 2-1/2
inches)
All colorimeter kits are supplied with enough reagents for at least 100
tests, six screw cap sample vials, an instruction manual and a sturdy
carrying case.
CAT.
NO. |
DESCRIPTION |
LAM3670-01 |
Single Test
Colorimeter model DC1200 (DPD tablet) |
LAM1773-00 |
Optional AC
adapter 110V/60Hz |
LAM1774-00 |
Optional AC
adapter 220V/50Hz |
Other single |
LAM368001- |
- Test factor: Ammonia Nitrogen
- Range (ppm): 0 - 5.0
- Detection limit: 0.05
- Test method (# of reagents): Nessler (2)
|
LAM367201- |
- Test factor: Bromine
- Range (ppm): 0 - 7.0
- Detection limit: 0.05
- Test method (# of reagents): DPD Tablets (1)
|
LAM367001- |
- Test factor: Chlorine (free & total)
- Range (ppm): 0 - 4.0
- Detection limit: 0.05
- Test method (# of reagents): DPD Tablets (2)
|
LAM367001-L1 |
- Test factor: Chlorine (free & total)
- Range (ppm): 0 - 4.0
- Detection limit: 0.05
- Test method (# of reagents): DPD Liquid (3)
|
LAM367101- |
- Test factor: Clorine Dioxide
- Range (ppm): 0 - 7.0
- Detection limit: 0.05
- Test method (# of reagents): DPD with Glycine Solution
(2)
|
LAM367301- |
- Test factor: Copper
- Range (ppm): 0 - 8.0
- Detection limit: 0.03
- Test method (# of reagents):
Diethyldithiocarbomate
|
LAM367401- |
- Test factor: Fluoride
- Range (ppm): 0 - 2.0
- Detection limit: 0.028
- Test method (# of reagents): Alizarin-Zirconyl
(2)
|
LAM368101- |
- Test factor: Iron
- Range (ppm): 0 - 4.0
- Detection limit: 0.25
- Test method (# of reagents): 1 - 10
Phenanthroline
|
LAM368201- |
- Test factor: Manganese
- Range (ppm): 0 - 0.9
- Detection limit: 0.01
- Test method (# of reagents): PAN (3)
|
LAM367601- |
- Test factor: Molybdenum
- Range (ppm): 0 - 50
- Detection limit: 0.5
- Test method (# of reagents): Thioglycolate (3)
|
LAM367701- |
- Test factor: Nitrate Nitrogen
- Range (ppm): 0 - 3.0
- Detection limit: 0.05
- Test method (# of reagents): Cadmium Reduction
(2)
|
LAM367801- |
- Test factor: Ozone
- Range (ppm): 0 - 0.4
- Detection limit: 0.04
- Test method (# of reagents): Indigo Blue (3)
|
LAM367901- |
- Test factor: Phosphate
- Range (ppm): 0 - 3.0
- Detection limit: 0.07
- Test method (# of reagents): Ascorbic Acid (2)
|
LAM368301- |
- Test factor: Sulfate
- Range (ppm): 0 - 100
- Detection limit: 0.1
- Test method (# of reagents): Barium Chloride
(1)
| |