single_test_colorimeter.jpg (51011 octets)The new 1200 Series of single test, direct reading colorimeters incorporates design advances that enhance reliability, improve accuracy, and simplify the calibration process, all in a portable, hand-held package.

Single test colorimeters are available for the following test factors: ammonia nitrogen, bromine, chlorine (free & total), chlorine dioxide, copper, fluoride, iron, manganese, molybdenum, nitrate nitrogen, ozone, phosphate and sulfate.

Features

  • Designed with excessive exposure to moisture in mind, the 1200 colorimeters deliver trouble-free performance in the field and lab.
  • The microprocessor enables the factory programmed calibrations to optimally match non-linear curves.
  • Simply insert the sample blank and press the zero key. No more dialing in the zero.
  • Flip-top lib over sample chamber prevents any stray light, especially in the field, and avoids misplacing separate light caps.
  • The large 3-1/2 digit display presents measurements in actual ppm concentration, and indicates low battery warnings.
  • An RS-232 port is provided to interface with a datalogger or computer.
  • The 1200 has been independently tested and has earned the European CE Mark of compliance for electromagnetic compatibility and safety.
  • An optional AC adapter is available to save battery when in the laboratory.

Specifications

  • Instrument type: single wavelength, direct-reading colorimeter
  • Readout: 3-1/2 digit LCD
  • Photometric accuracy: ±0.001 absorbance unit
  • Detector: Silicon photodiode
  • Sample chamber: accepts 25mm diameter, flat-bottom, capped test tubes (included)
  • Light source: LED
  • Interface: RS-232 serial interface
  • Power: Alkaline 9 Volt DC battery, 3.5mm jack for optional AC adapter
  • Size (LxWxH): 15 x 8 x 5.5 cm (6 x 3-1/4 x 2-1/2 inches)

All colorimeter kits are supplied with enough reagents for at least 100 tests, six screw cap sample vials, an instruction manual and a sturdy carrying case.

CAT. NO. DESCRIPTION
LAM3670-01 Single Test Colorimeter model DC1200 (DPD tablet)
LAM1773-00 Optional AC adapter 110V/60Hz
LAM1774-00 Optional AC adapter 220V/50Hz
Other single
LAM368001-
  • Test factor: Ammonia Nitrogen
  • Range (ppm): 0 - 5.0
  • Detection limit: 0.05
  • Test method (# of reagents): Nessler (2)
LAM367201-
  • Test factor: Bromine
  • Range (ppm): 0 - 7.0
  • Detection limit: 0.05
  • Test method (# of reagents): DPD Tablets (1)
LAM367001-
  • Test factor: Chlorine (free & total)
  • Range (ppm): 0 - 4.0
  • Detection limit: 0.05
  • Test method (# of reagents): DPD Tablets (2)
LAM367001-L1
  • Test factor: Chlorine (free & total)
  • Range (ppm): 0 - 4.0
  • Detection limit: 0.05
  • Test method (# of reagents): DPD Liquid (3)
LAM367101-
  • Test factor: Clorine Dioxide
  • Range (ppm): 0 - 7.0
  • Detection limit: 0.05
  • Test method (# of reagents): DPD with Glycine Solution (2)
LAM367301-
  • Test factor: Copper
  • Range (ppm): 0 - 8.0
  • Detection limit: 0.03
  • Test method (# of reagents): Diethyldithiocarbomate
LAM367401-
  • Test factor: Fluoride
  • Range (ppm): 0 - 2.0
  • Detection limit: 0.028
  • Test method (# of reagents): Alizarin-Zirconyl (2)
LAM368101-
  • Test factor: Iron
  • Range (ppm): 0 - 4.0
  • Detection limit: 0.25
  • Test method (# of reagents): 1 - 10 Phenanthroline
LAM368201-
  • Test factor: Manganese
  • Range (ppm): 0 - 0.9
  • Detection limit: 0.01
  • Test method (# of reagents): PAN (3)
LAM367601-
  • Test factor: Molybdenum
  • Range (ppm): 0 - 50
  • Detection limit: 0.5
  • Test method (# of reagents): Thioglycolate (3)
LAM367701-
  • Test factor: Nitrate Nitrogen
  • Range (ppm): 0 - 3.0
  • Detection limit: 0.05
  • Test method (# of reagents): Cadmium Reduction (2)
LAM367801-
  • Test factor: Ozone
  • Range (ppm): 0 - 0.4
  • Detection limit: 0.04
  • Test method (# of reagents): Indigo Blue (3)
LAM367901-
  • Test factor: Phosphate
  • Range (ppm): 0 - 3.0
  • Detection limit: 0.07
  • Test method (# of reagents): Ascorbic Acid (2)
LAM368301-
  • Test factor: Sulfate
  • Range (ppm): 0 - 100
  • Detection limit: 0.1
  • Test method (# of reagents): Barium Chloride (1)