MAIN MENU

CATALOG INDEX
BY ALPHABETICAL
ORDER

CATALOG INDEX
BY DEPARTMENT

For more info:
JSi@jsits.com

- [ 8 Eight Channel
Temperature Logger -
SmartReader 8 ]
- [ Data Logger & Software
Packages ]
- [ Display STARLOGGER
Model 6004-2 ]
- [ Eight-Channel Tempe-
rature Info Logger -

SmartReader Plus 8 ]
- [ Electric Current and
Temperature Info Logger
- SmartReader Plus 3 ]
- [ Electric Current and
Temperature Logger -
SmartReader 3 ]
- [ Hygro-Thermometer
Anemometer/Data Logger ]
- [ MACRO Data Logger
Model 7000 ]
- [ MACRO Tester model
7805A ]
- [ Memory Card STAR
LOGGER Model 6004-3 ]
- [ Multi-channel Thermo-
couple Info Logger -
SmartReader 6 ]
- [ Multi-channel Thermo-
couple Info Logger -
SmartReader Plus 6 ]
- [ Pressure, Temperature
and RH Info Logger -
SmartReader 4 ]
- [ Pressure, Temperature,
and RH Info Logger -
SmartReader Plus 4 ]
- [ Process Signal Info
Logger - SmartReader
Plus 7 ]
- [ Process Signal Logger -
SmartReader 7 ]
- [ Pulse Info Logger -
SmartReader Plus 9 ]
- [ Pulse Logger - Smart-
Reader 9 ]
- [ RF Remote Site
Monitoring Products ]
- [ Rugged MS-DOS 5.0
Hand-Held PC ]
- [ Standard STARLOGGER
Model 6004-1 ]
- [ Temperature and Rela-
tive Humidity Logger -
SmartReader 2 ]
- [ Temperature and Rela-
tive Humidity Logger -
SmartReader Plus 2 ]
- [ Temperature Info
Logger - SmartReader
Plus 1 ]
- [ Temperature Logger -
SmartReader 1 ]
- [ Thermocouple Info
Logger - SmartReader
Plus 5 ]
- [ Thermocouple Logger -
SmartReader 5 ]

Pressure, Temperature, and RH Info Logger - Smart Reader Plus 4
Smart Reader Plus model 4 data logger provides easy monitoring and troubleshooting of pneumatic control systems. The unit is completely self-contained with a 1/4" quick-release pressure fitting to allow a fast anf trouble-free connection. As an added bonus: SmartReader Plus model 4 can also monitor temperature internally, or temperature and RH externally. (RH sensors/probes and thermistor temperature probes sold separately).

Applications : Performance tracking of pneumatically controlled valves; verifying thermostat and humidistats; monitoring sensitive shipments.

Accessories : ACR EH-020A Relative Humidity/Temperature probe, ACR ET Series of Thermistor Temperature Probes; any NTC thermistor probe; (see ACR Accessories Catalog for more information).

Ordering information : Choose the correct pressure range for your applications. See specifications below for available models.

Specifications :

  • No. of Channels : Four. (One for ambient temperature, one for pressure, and 2 for the optional Relative Humidity/Temperature Probe)
  • Calibrated Accuracy : +/-0.5% of full scale @ 25°C (77°F)
Range Resolution Pressure Accuracy Thermal Accuracy Model /Catalog Number
        Gauge Absolute
+/-10" H2O 0.006 +/-2% FS @ 25°C (77°F) +/-3% FS 0 to 70°C (32 to 158°F) SRP-004-010 #01-0090 n/a
0 to 5 psi (30kPa) 0.003 psi (0.02kPa) +/-1% FS @ 25°C (77°F) +/-1.5% FS 0 to 70°C (32 to 158°F) SRP-004-5G #01-0090 n/a
0 to 30 psi (200kPa) 0.015 psi (0.10kPa) +/-0.5% FS @ 25°C (77°F) +/-0.5% FS 0 to 70°C (32 to 158°F) SRP-004-30G #01-0093 SRP-004-30A #01-0092
0 to 100 psi (700kPa) 0.05 psi (0.34kPa) +/-0.5% FS @ 25°C (77°F) +/-0.5% FS 0 to 70°C (32 to 158°F) SRP-004-100G #01-0095 SRP-004-100A #01-0094

Common Specifications :

  • Size : 107 x 74 x 22 mm (4.2" x 2.9" x 0.9")
  • Weight : 110 grams (3.75 ounces)
  • Case Material : Noryl Plastic
  • Operating Limits : -45°C to 70°C (-50°F to 160°F) and 0 to 95% Relative Humidity (non-condensing)
  • Clock-Accuracy : +/-2 seconds per day plus one sampling interval
  • Battery : 3.6 volt Lithium, 1 Amp-Hour
  • Power Consumption : 5 to 10 microamps (continuous)
  • Battery Life : Ten years (Factory Replaceable)
  • External Connector : Removable screw-type terminal strip with Common (-) connection
  • Memory Size : 21,500 readings
  • Sampling Methods :
    1. Continuous (First-in, First-out)
    2. Stop when full (Fill-then-stop)
  • Sampling Rates : User selectable rates from 25 per second to every 8 hours. (BP-100 battery pack required for sample rates less than 8 seconds)
  • Resolution : 12 bits (1 part in 4096)
  • PC Hardware Requirements : IBM PC or 100% compatible with: at least one free serial port;
  • Software Requirements : TrendReader for Windows-Windows version 3.1 or later already running with at least 2MB of RAM memory and 2MB of hard drive disk space
  • Product Approvals : Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emmisions repectively for the Commision of the European Communities (CE).
  • Resistance to X-Rays : Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"

Internal Temperature Sensor (common on all models):

  • Type : Negative Temperature Coefficient Thermistor.
    10,000 ohms @ 25°C (77°F).
  • Tolerance (sensor only) : +/-0.2°C, over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to 158°F).
  • Range : -40 to 70°C (-40 to 158°F)
  • Resolution : 0.03°C (0.05°F) at 25°C (77°F).
    Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C (158°F).
    Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C (-13°F).
CAT. NO.
_
DESCRIPTION
_
ACRSRP-004 10"WC.. Pressure, Temperature & RH Logger , 128K
ACRSRP-004 5G.......... Pressure, Temperature & RH Logger , 120K
ACRSRP-004-30A....... Pressure, Temperature & RH Logger , 120K
ACRSRP-004-30G........ Pressure, Temperature & RH Logger , 120K
ACRSRP-004-100A..... Pressure, Temperature & RH Logger , 120K
ACRSRP-004-100G...... Pressure, Temperature & RH Logger , 120K
ACRTR-WIN-SRP....... TrendReader includes everything needed to access information from any 12 bit SRP logger Windos version
ACREH-20A................. Remote RH & Temperature Sensing Probe
ACREH-016.................. General Purpose Temperature Probe
ACRPM-005-G............. 0-5 PSI Gauge
ACRPM-030-G............. 0-30 PSI Gauge
ACRPM-100-G............. 0-100 PSI Gauge
ACRPM-150-G............. 0-150 PSI Gauge
ACRPM-030-A............. 0-30 PSI Absolute
ACRPM-100-A............ 0-100 PSI Absolute
ACRHOSE-00............... 1/4" Pressure Hose