MAIN MENU

CATALOG INDEX
BY ALPHABETICAL
ORDER

CATALOG INDEX
BY DEPARTMENT

For more info:
JSi@jsits.com

- [ Portable Flue Gas /
Combustion Analyzer
Model Eurolyzer
]
- [ Portable Flue Gas /

Combustion Analyzer
Model ICA
]
- [ Portable Flue Gas /

Combustion Analyzer
Model Megacom
]

Portable Flue Gas / Combustion Analyzer Model: Eurolyzer

portable_flue_gas.jpg (11156 octets)Features:

  • Measures: Draft, O2,CO-H2 compensated, Flue gas and ambient Temperatures
  • Calculates: CO2, CO-undiluted, Efficiency and Losses
  • The sensors are safe for storage to -22°F (-30°C)
  • Economical, rugged and easy to operate
  • Ideal for monitoring and servicing residential or small heating systems
  • Selective filter protection for sensors ensures maximum service life
  • Optimum burner adjustment by displaying two readings simultaneously
  • Automatic self test and calibration
  • Integrated infrared printer interface

Specifications

Flue Gas Temperature:
Sensor: K-type Thermocouple
Range: 32° to 1,850°F (0° to 1,000°C)
Resolution: 1°F or °C
Accuracy: ±0.5% of reading
Ambient Room Temperature:
Sensor: K-type Thermocouple
Range: -5° to 395°F (-20° to 200°C)
Resolution: 0.5°F or °C
Accuracy: ±6°F / 3°C for <32°F (<0°C)
±2°F / 1°C for >32°F (>0°C)
Oxygen (O2) Measurement:
Sensor: Electro-chemical cell
Range: 0.0 to 20.9%
Resolution: 0.1%
Accuracy: ±0.2%
Carbon monoxide (CO) Measurement:
Sensor: Electro-chemical cell
Range: 0 to 4,000 ppm
Resolution: 1 ppm
Accuracy: ±5 ppm (up to 150 ppm)
±5% of reading (up to 4,000 ppm)
Draft Measurement:
Sensor: Semiconductor sensor
Range: ±16 inches H2O (±40 hPa)
Resolution: 0.01 in. H2O or hPa
Accuracy: ±0.08 inches H2O or ±0.2 hPa (up to 1.2 in. H2O)
±1% of reading (above 1.2 in. H2O)
Carbon dioxide (CO2) Calculation:
Calculated from O2 measurement
Range: 0.0 to CO2max %*
Resolution: 0.1%
Accuracy: ±0.2%
*CO2max % - Maximum CO2 value (relative to fuel) in %

Display: Dual line LCD
Datalink: Infrared (HP - protocol)
Operating Temperature: 50° to 104°F (10° to 40°C)
Storage Temperature: -22° to 140°F (-30° to 60°C)
Power Supply: 2 AA alkaline batteries
Battery Life: 12 hours
Dimensions: 7.25" X 2.4" X 1.4"
Weight: 15 Ounces instrument only

Items supplied with the EUROLYZER:
Factory calibrated and installed oxygen, carbon monoxide and draft sensors
2 pcs. AA batteries
1 pc. flue gas temperature probe / water trap and 6' hose assembly
1 pc. ambient temperature sensor
1 pc. protective holster with magnets
1 pc. carrying case
1 pc. instruction manual

Optional:
Hewlett Packard Infrared Printer PN 7110
120 VAC Power Supply PN 7111
Soot pump PN 7112
Immersion Temperature probe PN TK102
Surface Temperature probe PN TK103
Air Temperature probe PN TK104
Pipe Clamp-on Temperature probe PN TK107


NOTE:
PLEASE SPECIFY ENGLISH OR METRIC UNITS

English Units Metric Units
Temperature °F °C
Pressure inches H2O hPa