portable_flue_gas-ica.jpg (10522 octets)Features:

  • Measures: Draft, O2,CO-H2 compensated, Flue gas and ambient Temperatures
  • Calculates: CO2, CO-undiluted, Efficiency, Excess air (Lambda) and Losses
  • Optionally measures NO & SO2 and calculates NOx
  • The sensors are safe for storage to -22F (-30C)
  • Ideal for monitoring and servicing industrial combustion systems
  • 2 separate pumps for gas and flush operations
  • Datalogger can store 10 blocks of data
  • Selective filter protection for sensors ensures maximum service life
  • Integral printer and RS-232 serial interface
  • Displays eight readings simultaneously
  • Automatic self test and calibration

Specifications

Flue Gas Temperature:
Sensor: K-type Thermocouple
Range: 32to 1,850F (0to 1,000C)
Resolution: 1F or C
Accuracy: 2F / 1C (0to 400C)
0.5% of reading (up to 1,000C)
Ambient Room Temperature:
Sensor: K-type Thermocouple
Range: -5to 212F (-20° to 100C)
Resolution: 0.1F or C
Accuracy: 2F / 1C (0.1to 100C)
6F / 3C (-20to 0.0C)
Oxygen (O2) Measurement:
Sensor: Electro-chemical cell
Range: 0.0 to 20.9%
Resolution: 0.1%
Accuracy: ±0.2%
Carbon monoxide (CO) Measurement:
Sensor: Electro-chemical cell
Range: 0 to 2,000 ppm
Resolution: 1 ppm
Accuracy: 5 ppm (<150 ppm)
5% of reading (up to 2,000 ppm)
Draft Measurement:
Sensor: Semiconductor sensor
Range: 8.00 inches H2O or 19.99 mbar
Resolution: 0.01 inches H2O or mbar
Accuracy: 0.01 inches H2O / 0.02 mbar (<0.8 inches H2O)
0.1% of reading (0.8 to 8.0 inches H2O)
Carbon dioxide (CO2) Calculation:
Calculated from O2 measurement
Range: 0.0 to CO2max %*
Resolution: 0.1%
Accuracy: 0.2%
*CO2max % - Maximum CO2 value (relative to fuel) in %

Display: Four line LCD - eight readings (backlit)
Datalink: RS-232 serial port
Integral Printer: Seico with plain 60 mm paper
Operating Temperature: 50to 104F (10to 40C)
Storage Temperature: -22to 140F (-30to 60C)
Power Supply: 6V Ni Cad battery with charger
Battery Life: 20 hours
Dimensions: 9.5" X 4.0" X 8.25"
Weight: 7.2 lbs.

Items supplied with the ICA: pacer-indcom
Factory calibrated and installed oxygen, carbon monoxide and draft sensors
Rechargeable battery and charger
Built in printer
1 pc. flue gas temperature probe / watertrap with 8' hose assembly
1 pc. ambient temperature sensor
1 pc. carrying case
1 pc. instruction manual

Optional:
Soot pump PN 7112
Immersion Temperature probe PN TK102
Surface Temperature probe PN TK103
Air Temperature probe PN TK104
Pipe Clamp-on Temperature probe PN TK107
second separate gas pump PN 7133
Optional sensors:
Nitrogen monoxide (NO) Measurement: PN 7130
Sensor: Electro-chemical cell
Range: 0 to 2,000 ppm
Resolution: 1 ppm
Accuracy: 5 ppm (50 to 100 ppm)
5% of reading (up to 2000 ppm)
High Concentration Carbon monoxide (CO) Measurement: PN 7131
Sensor: Electro-chemical cell
Range: 0 to 10,000 ppm
Resolution: 100 ppm or 0.01% Vol
Sulfur dioxide (SO2) Measurement: PN 7132
Sensor: Electro-chemical cell
Range: 0 to 2,000 ppm
Resolution: 1 ppm
Accuracy: 5 ppm (<100 ppm)
5% of reading (up to 2000 ppm)
Draft Measurement (High Range):
Sensor: Piezoresistive semiconductor sensor
Range: 40.00 inches H2O or 99.99 mbar
Resolution: 0.01 inches H2O or mbar
Accuracy: 0.02 inches H2O / 0.05 mbar (up to 8.0 inches H2O)
1% of reading (8.0 to 40.0 inches H2O)
Nitrogen dioxide (NO2) Calculation:
Calculated from NO measurement
Range: 0 to 2,000 ppm
Resolution: 1 ppm