MAIN MENU

CATALOG INDEX
BY ALPHABETICAL
ORDER

CATALOG INDEX
BY DEPARTMENT

For more info:
JSi@jsits.com

- [ 8 Eight Channel
Temperature Logger -
SmartReader 8 ]
- [
Data Logger & Software
Packages ]
- [
Display STARLOGGER
Model 6004-2 ]
- [
Eight-Channel Tempe-
rature Info Logger -

SmartReader Plus 8 ]
- [
Electric Current and
Temperature Info Logger
- SmartReader Plus 3 ]
- [
Electric Current and
Temperature Logger -
SmartReader 3 ]
- [
Hygro-Thermometer
Anemometer/Data Logger ]
- [
MACRO Data Logger
Model 7000 ]
- [
MACRO Tester model
7805A ]
- [
Memory Card STAR
LOGGER Model 6004-3 ]
- [
Multi-channel Thermo-
couple Info Logger -
SmartReader 6 ]
- [
Multi-channel Thermo-
couple Info Logger -
SmartReader Plus 6 ]
- [
Pressure, Temperature
and RH Info Logger -
SmartReader 4 ]
- [
Pressure, Temperature,
and RH Info Logger -
SmartReader Plus 4 ]
- [
Process Signal Info
Logger - SmartReader
Plus 7 ]
- [
Process Signal Logger -
SmartReader 7 ]
- [
Pulse Info Logger -
SmartReader Plus 9 ]
- [
Pulse Logger - Smart-
Reader 9 ]
- [
RF Remote Site
Monitoring Products ]
- [
Rugged MS-DOS 5.0
Hand-Held PC ]
- [
Standard STARLOGGER
Model 6004-1 ]
- [
Temperature and Rela-
tive Humidity Logger -
SmartReader 2 ]
- [
Temperature and Rela-
tive Humidity Logger -
SmartReader Plus 2 ]
- [
Temperature Info
Logger - SmartReader
Plus 1 ]
- [
Temperature Logger -
SmartReader 1 ]
- [
Thermocouple Info
Logger - SmartReader
Plus 5 ]
- [
Thermocouple Logger -
SmartReader 5 ]

Pulse Logger - SmartReader 9

 

¿ëµµ: MÀ¯Ã¼ °¨½Ã, ¿¡³ÊÁö, ¾Öü ·¹º§, dz¼Ó, RPM, ´ë±â Á¶°Ç, °­¼ö·®µî µ¥ÀÌÅÍ ÀúÀå

»ç¾ç :

  ÀϹÝ:

  • ¿ÜÇü: 107 x 74 x 22 mm (4.2" x 2.9" x 0.9")
  • ¹«°Ô: 110 grams (5 ounces)
  • ÄÉÀ̽º ÀçÁú: Noryl Plastic
  • µ¿ÀÛ ¹üÀ§: -45¡ÆC to 70¡ÆC (-50¡ÆF to 160¡ÆF) and 0 to 95% Relative Humidity (non-condensing)
  • Ŭ·° Á¤È®µµ: +/-8 seconds per day plus one sampling interval
  • ¹èÅ͸®: 3.6 volt Lithium, 1 Amp-Hour
  • ¼­ºñ Àü·Â: 5 to 10 microamps (continuous)
  • ¹èÅ͸® ¼ö¸í: Ten years (Factory Replaceable)
  • ¿ÜºÎ ÄÚ³ØÅÍ: Removable screw-type terminal strip with Common (-) connection
  • ¸Þ¸ð¸® »çÀÌÁî: 32,768 readings
  • »ùÇøµ ¹æ¹ý:
    1. Continuous (First-in, First-out)
    2. Stop when full (Fill-then-stop)
  • »ùÇøµ ¾ç: User selectable rates from every 8 seconds to once a week
  • ºÐÇØ´É: 8 bits (1 part in 256)
  • PC Çϵå¿þ¾î ¿ä±¸»ç¾ç: IBM PC or 100% compatible with: at least one serial port; an IBM CGS, EGA, HGA, VGA, or other adapter capable of emulating thses standards
  • ¼ÒÇÁÆ®¿þ¾î:
    1. TrendReader for DOS-MS DOS version 3.0 or later and at least 512 K of RA memory. TrendReader for DOS supports a wide range of printers and plotters.
    2. TrendReader for Windows-Windos version 3.1 or later already running with at least 2MB of RAM memory and 2MB of hard drive disk space
  • Á¦Ç° ½ÂÀÎ: Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada and of Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC).
  • X-Ray¿¡ ´ëÇÑ ÀúÇ×Ä¡: Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.1337 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"

I³»ºÎ ¿Âµµ ¼¾¼­( Àü ¸ðµ¨)

  • Çü½Ä: Negative Temperature Coefficient Thermistor
  • R25 °ª: 10,000 ohms
  • ¿Ü°îµµ(sensor ) : +/-0.2¡ÆC, over the range of 0 to 70¡ÆC (+/-0.3¡ÆF, over the range of 32 to 158¡ÆF).
  • ¹øÀ§: -40 to 70¡ÆC (-40 to 158¡ÆF)
  • ºÐÇØ´É: 0.4¡ÆC (0.7¡ÆF). Better than 1¡ÆC (1.8¡ÆF) between -25¡ÆC (-13¡ÆF) and 70¡ÆC (158¡ÆF). Better than 2.0¡ÆC (3.6¡ÆF) between -40¡ÆC (-40¡ÆF) and -25¡ÆC (-13¡ÆF).

»ç¾ç:

  • ä³Î ¼ö: Three (one internal, for ambient temperature and two external for externally-generated pulse signals and dry switch contact closures).
  • ¹üÀ§: 32 pulses/second; 64 pulses/second; 1288 pulses/second
  • Àüü ÃøÁ¤ ½Ã°£ : Eight seconds. Average frequency of pulse rate over this period must not exceed the range of the channel used or total will restart from zero
  • Ä«¿îÆ® Á¤È®µµ:
    • 32 Hz channel : ¡¾1 pulse/8 seconds
    • 64 Hz channel : ¡¾2 pulse/8 seconds
    • 128 Hz channel : ¡¾4 pulse/8 seconds

    Switch contact closure inputs (internally generated voltage pulses)

  • ÀÔ·Â Çü½Ä: Uncommitted switch or relay contacts ("dry" contacts)
  • Àü±â ÀÚ±Ø: 5 microamps contact current, +3.6 volts, open circuit
  • ÃÖ¼Ò ÆÞ½º Æø: 4 milliseconds

Ext. Switch Contact

  • ¿ä±¸»çÇ×: Gold-plated sealed contacts
  • ÀÔ·Â Çü½Ä: Active logic signals
  • ÀÔ·Â Àü¾Ð: 0 to 0.5 volts (D.C.), low/4.5 to 24 volts (D.C.) high
  • ÀÔ·Â ÀÓÇÇ´ø½º: 750 kohms

CAT. NO.
_

DESCRIPTION
_

ACRSR009-0.......

Pulse & Temperature Logger.

ACRTRSFW-0....

TrendReader software with IC-100 cable