- [ 8
Eight Channel Temperature Logger -
SmartReader
8 ] - [ Data
Logger & Software Packages ] - [
Display
STARLOGGER Model 6004-2
] - [ Eight-Channel
Tempe- rature Info Logger - SmartReader Plus 8
] - [ Electric
Current and Temperature Info
Logger -
SmartReader Plus 3 ] - [ Electric Current and
Temperature
Logger - SmartReader 3
] - [ Hygro-Thermometer
Anemometer/Data
Logger ] - [ MACRO Data Logger
Model
7000 ] - [ MACRO Tester
model 7805A ] - [ Memory Card STAR
LOGGER
Model 6004-3 ] - [ Multi-channel
Thermo- couple
Info Logger - SmartReader 6 ] -
[ Multi-channel
Thermo- couple Info Logger -
SmartReader
Plus 6 ] - [ Pressure,
Temperature and RH Info Logger -
SmartReader
4 ] - [ Pressure,
Temperature, and RH Info Logger -
SmartReader
Plus 4 ] - [ Process Signal Info
Logger -
SmartReader Plus 7 ] - [ Process Signal Logger
- SmartReader
7 ] - [ Pulse Info Logger -
SmartReader
Plus 9 ] - [ Pulse Logger - Smart-
Reader 9
] - [ RF Remote
Site Monitoring Products
] - [ Rugged MS-DOS
5.0 Hand-Held
PC ] - [ Standard
STARLOGGER Model 6004-1
] - [ Temperature
and Rela- tive Humidity Logger -
SmartReader
2 ] - [ Temperature and
Rela- tive
Humidity Logger - SmartReader Plus 2
] - [ Temperature Info
Logger -
SmartReader Plus 1 ] - [ Temperature Logger
- SmartReader
1 ] - [ Thermocouple
Info Logger
- SmartReader Plus 5 ] - [ Thermocouple Logger
- SmartReader
5 ] |
Pulse Info Logger - Smart
Reader Plus 9
The SmartReader Plus model 9 is a
versatile data logger designed for easy counting and recording of
switch contact closures and voltage pulses. It has two pulse/contact
input channels. Data can be displayed in custom engineering units
using the simple equation editor of ACR's TrendReader for Windows
Software. |
|
Applications : Monitoring fluid and air flow, energy
use, wind speed, shaft RPM and rainfall.
Specifications :
- No. of Channels : Two. (Two external
inputs for externally-generated pulse signals and dry switch contact
closures).
- Minimum Pulse Width : 2
milliseconds.
- Switch Contact Closure Input :
- Input type : Uncommitted swtich or relay
contacts.
- Logic Inputs :
- Logic type : Active logic signals.
- Input voltage :
- Low = 0 to 0.5 volts (DC).
- High = 4.5 to 24 volts (DC).
- Maximum Frquency : 512 Hz.
- Input Impedance : 750 K ohm
Common Specifications :
- Size : 107 x 74 x 22 mm (4.2" x 2.9" x
0.9")
- Weight : 110 grams (3.75
ounces)
- Case Material : Noryl Plastic
- Operating Limits : -45°C to 70°C
(-50°F to 160°F) and 0 to 95% Relative Humidity (non-condensing)
- Clock-Accuracy : +/-2 seconds per day
plus one sampling interval
- Battery : 3.6 volt Lithium, 1
Amp-Hour
- Power Consumption : 5 to 10 microamps
(continuous)
- Battery Life : Ten years (Factory
Replaceable)
- External Connector : Removable
screw-type terminal strip with Common (-) connection
- Memory Size : 21,500 readings
- Sampling Methods :
- Continuous (First-in, First-out)
- Stop when full (Fill-then-stop)
- Sampling Rates : User selectable rates
from 25 per second to every 8 hours. (BP-100 battery pack required for
sample rates less than 8 seconds)
- Resolution : 12 bits (1 part in
4096)
- PC Hardware Requirements : IBM PC or
100% compatible with: at least one free serial port;
- Software Requirements : TrendReader
for Windows-Windows version 3.1 or later already running with at least
2MB of RAM memory and 2MB of hard drive disk space
- Product Approvals : Meets Part 15 for
Digital Devices of the Code of Federal Regulations of the Federal
Communications Commission (FCC). Meets Class A radiated and conducted
emission requirements of Section 2 of the Radio Interference Regulations
of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI
Immunity, EFT/Burst and Radiated Emmisions repectively for the Commision
of the European Communities (CE).
- Resistance to X-Rays : Tested for
protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38
inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested
for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts)
IR 192 - 28 curies @ 30 second exposure source to object distance
5"
Internal Temperature Sensor (common on all
models):
- Type : Negative Temperature
Coefficient Thermistor.
10,000 ohms @ 25°C (77°F).
- Tolerance (sensor only) : +/-0.2°C,
over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to
158°F).
- Range : -40 to 70°C (-40 to
158°F)
- Resolution : 0.03°C (0.05°F) at 25°C
(77°F).
Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C
(158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C
(-13°F).
CAT.
NO. _ |
DESCRIPTION _ |
ACRSRP-009............. |
Pulse Logger |
ACRTR-WIN-SRP.... |
TrendReader - includes everything needed
to access information from any 12 bit srp logger Windows
version | |