- [ Portable
Flue Gas / Combustion
Analyzer Model Eurolyzer ] - [ Portable
Flue Gas / Combustion
Analyzer Model ICA ] - [ Portable Flue Gas
/ Combustion
Analyzer Model
Megacom ]
|
Portable Flue Gas /
Combustion Analyzer Model: Megacom
Features
- Measures: Draft, O2,CO-H2 compensated, Flue
gas and ambient Temperatures
- Calculates: CO2, CO-undiluted, Efficiency, Excess air
(Lambda) and Losses
- Optionally measures NO and calculates NOx
- The sensors are safe for storage to -22°F (-30°C)
- Ideal for monitoring and servicing commercial or small industrial
combustion systems
- 2 separate pumps for gas and flush operations
- Datalogger can store 100 blocks of data
- Selective filter protection for sensors ensures maximum service life
- Displays four readings simultaneously
- Automatic self test and calibration
- Integrated infrared printer and RS-232 serial interface
Specifications
- Flue Gas Temperature:
-
Sensor: |
K-type Thermocouple |
Range: |
32° to 1,850°F (0° to 1,000°C) |
Resolution: |
1°F or °C |
Accuracy: |
±2°F / 1°C (0° to 400°C) ±0.5% of reading (up to 1,000°C)
|
- Ambient Room Temperature:
-
Sensor: |
K-type Thermocouple |
Range: |
-5° to 212°F (-20° to 100°C) |
Resolution: |
0.1°F or °C |
Accuracy: |
±1°F / 0.5°C |
- Oxygen (O2) Measurement:
-
Sensor: |
Electro-chemical cell |
Range: |
0.0 to 20.9% |
Resolution: |
0.1% |
Accuracy: |
±0.2% |
- Carbon monoxide (CO) Measurement:
-
Sensor: |
Electro-chemical cell |
Range: |
0 to 2,000 ppm |
Resolution: |
1 ppm |
Accuracy: |
±5 ppm (50 to 150 ppm) ±5% of reading (up to 2,000 ppm)
|
- Draft Measurement:
-
Sensor: |
Semiconductor sensor |
Range: |
±60 inches H2O or ±150 hPa |
Resolution: |
0.01 in. H2O or hPa |
Accuracy: |
±0.08 inches H2O or ±0.2 hPa (up to 0.8 in.
H2O) ±1% of reading (0.8 to 8.0 in.
H2O) ±3% of reading (above 8.0 in. H2O)
|
- Carbon dioxide (CO2) Calculation:
-
|
Calculated from O2 measurement |
Range: |
0.0 to CO2max %* |
Resolution: |
0.1% |
Accuracy: |
±0.2% |
|
*CO2max % - Maximum CO2 value (relative
to fuel) in %
|
Display: |
128 X 64 pixel Graphic LCD |
Datalinks: |
Infrared (HP - protocol) RS-232 serial port
|
Operating Temperature: |
40° to 104°F (5° to 40°C) |
Storage Temperature: |
-22° to 140°F (-30° to 60°C) |
Power Supply: |
6V Ni Cad battery with charger |
Dimensions: |
9.5" X 3.6" X 2.4" |
- Items supplied with the MEGACOM:
-
|
Factory calibrated and installed oxygen, carbon monoxide and
draft sensors Rechargeable battery and charger 1 pc. flue
gas temperature probe / water trap and 8' hose assembly 1 pc.
ambient temperature sensor 1 pc. carrying case 1 pc.
instruction manual
|
- Optional:
|
Hewlett Packard Infrared Printer PN 7110 120 VAC Power
Supply PN 7111 Soot pump PN 7112 Optional sensors:
|
- Nitrous oxide (NO) Measurement:
-
|
Sensor: |
Electro-chemical cell |
|
Range: |
0 to 2,000 ppm |
|
Resolution: |
1 ppm |
|
Accuracy: |
±5 ppm (50 to 150 ppm) ±5% of reading (up to 2,000
ppm) |
- High Concentration Carbon monoxide (CO)
Measurement:
-
|
Sensor: |
Electro-chemical cell |
|
Range: |
0 to 20,000 ppm |
|
Resolution: |
5 ppm |
|
Accuracy: |
±5 ppm |
- Nitrogen dioxide (NO2) Calculation:
-
|
|
Calculated from NO measurement |
|
Range: |
0 to 2,000 ppm |
|
Resolution: |
1 ppm |
|
Accuracy: |
±5 ppm |
Immersion Temperature probe PN TK102 Surface Temperature probe PN
TK103 Air Temperature probe PN TK104 Pipe Clamp-on Temperature probe
PN TK107
|