MAIN
MENU
CATALOG INDEX BY ALPHABETICAL ORDER
CATALOG
INDEX BY DEPARTMENT
For more info: JSi@jsits.com
- [ External Temperature
/ Humidity Sensor ] - [ Heavy Duty
Moisture Meter ] - [ Humidity
- Temperature Data logger
HygroLog ] - [ Humidity-Temperature Indicating
Probes ] - [ Humidity
- Temperature Indicator
A1H ] - [
Humidity
Temperature Meteorological Probe
- MP101A
] -[ Humidity
Temperature Meteorological
Probe ] - [ Humidity &
Temperature Meter ] - [ Humidity
- Temperature Transmitters
Calibration Free FH
Series ] - [ Leaf Wetness Sensor
] - [ Portable
Humidity Temperature Indicator - HygroPalm ] - [ Relative
Humidity Sensor ] - [ Temperature
Humidity Dew Point ] - [ TH-Calc
Temperature and Humidity
Meters ] |
Humidity-Temperature
Indicating Probes
- High accuracy, fast response probes
- 0..100%RH humidity measuring range
- Durable, stable sensors with low maintenance
requirements
- Simple, accurate humidity field calibration
- 3 different basic configurations to suit most
applications
- Ideal for Trouble-Shooting and Quality Assurance
PM1 probes Tubular
probe for the measurement of hygroscopic materials in bulk: powders,
granules or pellets. Typical areas of application include pharmaceutical
powders, powdered sugar, dried foods, beverages in powder form, coffee and
cocoa beans, tea leaves, cereals, seeds, etc.
PM1 Set Measures
the relative humidity and temperature of hygroscopic materials in bulk:
powders, granules or pellets.
The "quality assurance" tool for the drying of seeds,
coffee beans, animal feeds, sugar and for the manucfacturing of
pharmaceutical powders.
Specifications
- Humidity sensor: Rotronic Hygromer
C80
- Temperature sensor: PT 100 RTD
- Temperature limits: 20-130°F (-5 to
55°C)
- Measuring range: 0 to 100 %RH
20 to
130°F (-5 to 55°C)
- Humidity accuracy: ±2.0 %RH @
77°F
- Temperature accuracy: ±0.5°F (0.3°C)
at 77°F (25°C)
- RH sensor hysteresis: ±3 %RH,
Max.
- Typical long term stability: 1 %RH or
better over one year
- Sensors time constant: 10 seconds or
better
- Display: LCD, 3-1/2 digits
- Resolution: 0.1 %RH and 0.1°F or
0.1°C
- Battery: Standard 9V Alkaline
battery
- Calibration adjustment: 35, 80, 10
%RH
T0 and T40
- Calibration device: EGL
- Humidity standards:
EA05-10-20-35-50-65-80-95 %RH
- Sensor protection: dust filter FF10
(standard)
- Probe dimensions: 280 x 10 mm
- Overall case dimensions: 190 x 63 x 26
mm
- Weight: 360g (0.8lb)
CAT. NO. |
DESCRIPTION |
ROPM1-0000........... |
Humidity-temperature
probe | |