FT/IR-400Plus Series
JASCO's FT/IR-400 Plus Series
The new FT/IR-400Plus series
has been designed for efficient and user-friendly routine analysis. The
innovative hardware technology incorporated into this range of products
provides a remarkable increase in the signal to noise ratio when compared
with the FT/IR-400 Series. In addition, the user friendly features of
the FT/IR-400Plus allows the operator to measure samples much more quickly
and easily using the JASCO Quick Start System. The addition of a Quick
Start button together with JASCOs Quick Start Measurement software allows
the user to perform routine measurement as well as automatic data processing
functions all at a single push of a button. Simply from "Press to
Print" it couldn't be easier.
Click
here if you would like to receive more information on the FT/IR-400Plus
FT/IR-400Plus Series
Features of all 400Plus Series Models:
|
Quick Start button and Quick Start
program
|
|
ARAS accessory system
|
|
Quick Start button and Quick Start
program
|
|
Innovative patented ceramic source,
with all the features described above, provides high light output
and excellent signal to noise.
|
|
High intensity ceramic source "stand-by
mode" when the instrument is not in use protects the source
from damaging thermal shock. Residual heat from the source protects
the optics from any possibility of moisture ingress and ensures
minimum stabilisation time when the instrument is switched on.
|
|
Alignment free corner cube mirrors.
|
|
Temperature stabilised high performance
Deuterated L-Alanine Triglycine Sulphate (DLATGS) detector for high
sensitivity measurements with a standard detector.
|
|
Additional detector position for MCT
with switching mirror and software auto selection.
|
|
Sealed*, maintenance free interferometer
(*Purgeable if required).
|
|
FT/IR-420/430 (5000-220 cm-1)
Caesium Iodide/KRS-5 instruments available.
|
|
External beam configuration for (IRT-30)
Microscope upgrade path.
|
|
Rear access to electronic modules
for easy maintenance.
|
|
Vibration isolated optical bench.
|
|
Spectra Manager TM for
Windows 95/NT.
|
|
Choice of manual or automatic instrument
validation.
|
|
Validation
Software
|
|
Quantitative Software
|
|
JASCO Canvas for customised reports
|
|
Accepts OEM IR accessories like the
Golden Gate, PIKE, SensIR.
|
Go
to top of page
Features
High S/N Ratio
Due to improvements in components
and also in production efficiency a remarkably high S/N ratio is achieved:
15000:1 for the FT/IR-460. 22000:1 for the
FT/IR-470 and 24000:1 for the FT/IR-480. In addition,
a peltier element has been added to the DLATGS detector to maintain optimum
temperature in order to ensure maximum sensitivity.
Newly developed KRS-5 windows
Newly developed KRS-5 materials
have been used for the windows of the DLATGS detector and of the interferometer,
making the new FT/IR-400Plus series even more stable and robust without
sacrificing performance.
Quick Start button
All models in the FT/IR-400Plus
series have a Quick Start button which, when used with the Quick Start
program, allows the user to perform measurement easily and quickly. This
new feature is ideal for routine analysis and QC operation required when
measuring multiple samples.
Auto Recognition Accessory System
This series includes a new
Auto Recognition Accessory System that employs Logical Interface Control
(LINC) technology. Once an accessory has been registered, the system recognises
the accessory as soon as it is attached and its measurement parameters
are automatically set. The Auto Accessory Recognition feature removes
the necessity for repetitive and troublesome parameter settings and can
help avoid mistakes made due to incorrect parameter settings. The accessories
that can be recognized by the system are not limited to those made by
JASCO. By registering attachments beforehand, accessories made by other
companies can also be recognized by the system.
Simple operation mode
Having considered how our
customers use our instruments, JASCO now offers two different operation
modes. For high-level research analysis, JASCOs cross platform software
suite, Spectra Manager, provides a wide range of advanced features and
functions that allow precise measurement and detailed data analysis. For
routine and QC operations, JASCO’s new Quick Start System has been added
which allows quick, easy-to-use measurement and data analysis. With the
new JASCO Quick Start System you can.....
|
Start measurements
with a single push of a button. After pre-setting a measurement
sequence, measurement can be performed by simply pushing the Quick
Start button on the instrument or clicking the Start button on
the tool bar of the Quick Start Measurement program.
|
|
Perform measurement
and data analysis with no previous knowledge of the instrument
and/or minimal computer expertise. Using the mouse, simply select
the measurement, data analysis, print and / or save items you
require for your measurement sequence and you are ready to start
measurement.
|
|
Set a password
to prevent unauthorized people from accessing and changing parameter
settings.
|
When JASCO Quick Start is
used together with JASCOs new Auto Recognition Accessory System (ARAS),
accessories can be changed over and measurement performed more quickly
and easily than ever before.
Go
to top of page
FT/IR Manual Validation
Software
In order to comply with
GLP, GMP and ISO-9000 a complete validation program is supplied with all
FT/IR-400 Series instruments.
The software is easy to
use and checks the following criteria:-
Click on any of the above
tests - to see an example printout from the validation software
in acrobat format.
An additional software controlled
filter wheel (Validation Autosampling) may be fitted to the FT/IR-400
series which fully integrates with the validation software and automates
the testing procedure.
Tutorial software
Tutorial software that explains
the technique of FT/IR spectroscopy informs inexperienced operators on
the correct way to measure samples is now supplied with the instrument
on CD. The tutorial provides step-by-step explanations of measurement
methods such as Diffuse Reflectance (DR) and Attenuated Total Reflectance
(ATR).
Specifications
|
FT/IR-460
|
FT/IR-470
|
FT/IR-480
|
Measurable W.N. range
|
7800 - 350 cm -1
15000
- 2200 cm -1 (option, NIR model)
5000
- 220 cm -1 (factory option, Far-IR model)
|
Resolution
|
0.9, 2, 4, 8, 16 cm -1
|
0.5, 1, 2, 4, 8, 16 cm -1
|
Optical system
|
Single beam
|
Aperture diameter
|
fixed
|
Sample compartment
|
175 (W) x 255 (D) x 170 (H) mm
|
Beam diameter onto sample
|
4 mmf
|
Light path in sample compartment
|
Center focus, light axis 70 mmH
|
Interferometer
|
45 deg. incident Michelson interferometer,
corner cube mirror, sealed structure, purgeable
|
Interferometer drive mechanism
|
Mechanical bearing, electromagnetic
drive
|
Interferometer drive speed
|
Variable by software
|
Rapid scan
|
Option (10 spectra/sec., 16 cm -1
resolution)
|
Beam splitter
|
Ge coated KBr substrates, CaF 2 (option,
NIR model), CsI (factory option, Far-IR model)
|
Interferometer window material
|
KRS-5
|
Light source
|
High-intensity light source, Halogen
lamp (Option)
|
Detector
|
DLATGS with Peltier element(KRS-5),
MCT-N (- 750 cm -1 ) option, MCT-M (- 650 cm -1 ) option, MCT-W
(- 450 cm -1 ) option, InSb option, Silicon-photodiode (option).
Up to two detectors can be located simultaneously.
|
S/N ratio
|
15000:1
|
22000:1
|
24000:1
|
|
(4 cm -1 , 1 min, near 2200 cm -1
, p-p measurement with KRS-5 window)
|
GAIN switching
|
Manual operation at 1, 2, 4, 8, 16,
32, 64, 128, 256, 512, 1024, 2048 times (12 steps)
Auto gain at 1, 2, 4, 8, 16, 32, 64, 128, 256, 512 (10 steps)
|
A/D converter
|
16 bit + gain-ranging
|
18 bit + gain-ranging
|
100% T line flatness
|
less than 100 1.0% (4000 - 700 cm-1,
continuous measurement)
|
Dimensions
|
590(W) x 550(D) x 257(H) mm
|
Weight Approx.
|
41 kg
|
Power requirement
|
AC 100~240/font>10
V, 50 or 60H,
|
Standard Accessories
|
Main Unit 1 off
|
|
Spectra Manager Software with Quick
Start program
|
|
Validation
for FT/IR-400 Series (Manual Version requires
6713-F429A filter for validation)
|
|
Quantitative software
|
|
Instruction Manual 1 copy
|
|
Pin for setting accessories 2 pcs.
|
|
Power cable 1 pc.
|
|
Polystyrene film 1 pc.
|
|
Spare fuse 4 pcs.
|
|
ARAS Accessory Unit
|
Go
to top of page
Click
here to see the FT/IR-400Plus Series specification sheet - Acrobat
Format (28Kb)
Ordering Information (UK & Eire only)
PART
NUMBER
|
DESCRIPTION
|
6812-J006A
|
FT/IR-460
PLUS FT/IR Spectrometer
|
6812-J007A
|
FT/IR-470
PLUS FT/IR Spectrometer
|
6812-J008A
|
FT/IR-480
PLUS FT/IR Spectrometer
|
6812-J034A
|
FT/IR-470
PLUS FT/IR Spectrometer (Far IR model)
|
6812-J035A
|
FT/IR-480
PLUS FT/IR Spectrometer (Far IR model)
|
6812-U006A
|
FT/IR-460
PLUS Automated Validation Spectrometer System
Includes:
6812-J006A
FT/IR-460 PLUS Spectrometer
6748-F143A
Validation autosampling
1537
SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card
2930U-FTIR
AHA-2930U Adaptec PCI card
Requires:
A suitably configured PC
|
6812-U006M
|
FT/IR-460
PLUS Manual Validation Spectrometer System
Includes:
6812-J006A
FT/IR-460 PLUS Spectrometer
6713-F429A
Cut off filter for FTIR manual validation
1537
SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card
2930U-FTIR
AHA-2930U Adaptec PCI card
Requires:
A suitably configured PC
|
6812-U007A
|
FT/IR-470
PLUS Automated Validation Spectrometer System
Includes:
6812-J007A
FT/IR-470 PLUS Spectrometer
6748-F143A
Validation autosampling
1537
SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card
2930U-FTIR
AHA-2930U Adaptec PCI card
Requires:
A suitably configured PC
|
6812-U007M
|
FT/IR-470
PLUS Manual Validation Spectrometer System
Includes:
6812-J007A
FT/IR-470 PLUS Spectrometer
6713-F429A
Cut off filter for FTIR manual validation
1537
SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card
2930U-FTIR
AHA-2930U Adaptec PCI card
Requires:
A suitably configured PC
|
6812-U008A
|
FT/IR-480
PLUS Automated Validation Spectrometer System
Includes:
6812-J008A
FT/IR-480 PLUS Spectrometer
6748-F143A
Validation autosampling
1537
SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card
2930U-FTIR
AHA-2930U Adaptec PCI card
Requires:
A suitably configured PC
|
6812-U008M
|
FT/IR-480
PLUS Manual Validation Spectrometer System
Includes:
6812-J008A
FT/IR-480 PLUS Spectrometer
6713-F429A
Cut off filter for FTIR manual validation
1537
SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card
2930U-FTIR
AHA-2930U Adaptec PCI card
Requires:
A suitably configured PC
|
Go
to top of page
Optional Accessories
PART
NUMBER
|
DESCRIPTION
|
6748-F143A
|
Validation
autosampling (Factory Fitted), includes validation software,
automatic polystyrene and cut off filter insertion filter wheel
mechanism within the instrument
|
6713-F429A
|
Filter
for FTIR manual validation
|
4880-0523A
|
Macro
command program
|
4880-0702X
|
JASCO
Library search program
|
4880-0703X
|
Interval
scanning program
|
4880-0701X
|
Quantitative
analysis
|
2930U-FTIR
|
AHA2930U
Adaptec PCI card for FT/IR-400 and 600 series
|
1537
|
SCSI-1
to SCSI-2 Cable for AHA-2930U Adaptec PCI card
|
6748-J202A
|
MCT
(Mercury Cadmium Telluride) Detector mid range 15000-650 cm-1
includes detector switching mechanism Note: Requires Liquid Nitrogen
Cooling
|
6748-J203A
|
MCT
(Mercury Cadmium Telluride) Detector wide range 15000-450 cm-1
includes detector switching mechanism Note: Requires Liquid Nitrogen
Cooling
|
6749-J213A
|
InSb,
requires liquid N2 (15,000-1000cm-1 range) with mirror switching
mechanism
|
6749-J211A
|
DTGS
(Polyethylene window) 700-50cm-1 range with mirror switching mechanism
|
6749-J212A
|
MCT
(mid range), LN2 (10,000-650cm-1 range) with mirror switching
mechanism
|
6786-J006A
|
IRT-30-32E
InfraRed Microscope x32 Cassegrainian for FT/IR-400 Series
|
6786-J005A
|
IRT-30-16E
InfraRed Microscope x16 Cassegrainian for FT/IR-400 Series
|
6786-J033A
|
IPS-30E
IR Profile System X-Y-Z Stage autofocus & Software
|
6694-J122A
|
PL-200
Infra-Red polarisation accessory (factory option)
|
6690-J108A
|
ATR-JC-Z
ATR Objective, ZnSe Prism Cassegrain
|
6690-J111A
|
ATR-VZ
ATR Objective, ZnSe Prism (Viewable type) Cassegrain
|
6690-J109A
|
ATR-JC-G
ATR Objective, Ge Prism Cassegrain
|
6694-J133A
|
PL-E
Polariser for visible observation
|
6668-J111A
|
RAS-200
Grazing angle reflectance attachment (PL-200 is also required)
|
6668-J024A
|
RAS-500
Grazing angle reflectance attachment (PL-200 is also required)
|
|
|
|