Chromatography & Spectroscopy Products

 e-mail Jsi@Jsits.com 

 

FT/IR-400Plus Series 

JASCO's FT/IR-400 Plus Series 

The new FT/IR-400Plus series has been designed for efficient and user-friendly routine analysis. The innovative hardware technology incorporated into this range of products provides a remarkable increase in the signal to noise ratio when compared with the FT/IR-400 Series. In addition, the user friendly features of the FT/IR-400Plus allows the operator to measure samples much more quickly and easily using the JASCO Quick Start System. The addition of a Quick Start button together with JASCOs Quick Start Measurement software allows the user to perform routine measurement as well as automatic data processing functions all at a single push of a button. Simply from "Press to Print" it couldn't be easier.

Click here if you would like to receive more information on the FT/IR-400Plus

FT/IR-400Plus Series

Features of all 400Plus Series Models:

Quick Start button and Quick Start program
ARAS  accessory system
Quick Start button and Quick Start program
Innovative patented ceramic source, with all the features described above, provides high light output and excellent signal to noise.
High intensity ceramic source "stand-by mode" when the instrument is not in use protects the source from damaging thermal shock. Residual heat from the source protects the optics from any possibility of moisture ingress and ensures minimum stabilisation time when the instrument is switched on.  
Alignment free corner cube mirrors.
Temperature stabilised high performance Deuterated L-Alanine Triglycine Sulphate (DLATGS) detector for high sensitivity measurements with a standard detector.
Additional detector position for MCT with switching mirror and software auto selection.
Sealed*, maintenance free interferometer (*Purgeable if required).
FT/IR-420/430 (5000-220 cm-1) Caesium Iodide/KRS-5 instruments available.
External beam configuration for (IRT-30) Microscope upgrade path.
Rear access to electronic modules for easy maintenance.
Vibration isolated optical bench.
Spectra Manager TM  for Windows 95/NT.
Choice of manual or automatic instrument validation.
Validation Software
Quantitative Software
JASCO Canvas for customised reports
Accepts OEM IR accessories like the Golden Gate, PIKE, SensIR. 

Go to top of page

Features

High S/N Ratio

Due to improvements in components and also in production efficiency a remarkably high S/N ratio is achieved: 15000:1 for the FT/IR-460. 22000:1 for the FT/IR-470 and 24000:1 for the FT/IR-480. In addition, a peltier element has been added to the DLATGS detector to maintain optimum temperature in order to ensure maximum sensitivity. 

Newly developed KRS-5 windows

Newly developed KRS-5 materials have been used for the windows of the DLATGS detector and of the interferometer, making the new FT/IR-400Plus series even more stable and robust without sacrificing performance. 

Quick Start button

All models in the FT/IR-400Plus series have a Quick Start button which, when used with the Quick Start program, allows the user to perform measurement easily and quickly. This new feature is ideal for routine analysis and QC operation required when measuring multiple samples.

Auto Recognition Accessory System

This series includes a new Auto Recognition Accessory System that employs Logical Interface Control (LINC) technology. Once an accessory has been registered, the system recognises the accessory as soon as it is attached and its measurement parameters are automatically set. The Auto Accessory Recognition feature removes the necessity for repetitive and troublesome parameter settings and can help avoid mistakes made due to incorrect parameter settings. The accessories that can be recognized by the system are not limited to those made by JASCO. By registering attachments beforehand, accessories made by other companies can also be recognized by the system.

Simple operation mode

Having considered how our customers use our instruments, JASCO now offers two different operation modes. For high-level research analysis, JASCOs cross platform software suite, Spectra Manager, provides a wide range of advanced features and functions that allow precise measurement and detailed data analysis. For routine and QC operations, JASCO’s new Quick Start System has been added which allows quick, easy-to-use measurement and data analysis. With the new JASCO Quick Start System you can.....

Start measurements with a single push of a button. After pre-setting a measurement sequence, measurement can be performed by simply pushing the Quick Start button on the instrument or clicking the Start button on the tool bar of the Quick Start Measurement program.

Perform measurement and data analysis with no previous knowledge of the instrument and/or minimal computer expertise. Using the mouse, simply select the measurement, data analysis, print and / or save items you require for your measurement sequence and you are ready to start measurement.

Set a password to prevent unauthorized people from accessing and changing parameter settings.

When JASCO Quick Start is used together with JASCOs new Auto Recognition Accessory System (ARAS), accessories can be changed over and measurement performed more quickly and easily than ever before. 

Go to top of page

FT/IR Manual Validation Software

In order to comply with GLP, GMP and ISO-9000 a complete validation program is supplied with all FT/IR-400 Series instruments.

The software is easy to use and checks the following criteria:-

Total Inspection Report (8Kb)

Background Energy (18Kb)

Wavenumber Accuracy (17Kb)

Wavenumber Repeatability (43Kb)

Transmittance Repeatability (43Kb)

Resolution (11Kb)

%T Change (10kb)

Click on any of the above tests - to see an example printout  from the validation software in acrobat format.

An additional software controlled filter wheel (Validation Autosampling) may be fitted to the FT/IR-400 series which fully integrates with the validation software and automates the testing procedure.

Tutorial software

Tutorial software that explains the technique of FT/IR spectroscopy informs inexperienced operators on the correct way to measure samples is now supplied with the instrument on CD. The tutorial provides step-by-step explanations of measurement methods such as Diffuse Reflectance (DR) and Attenuated Total Reflectance (ATR).

Specifications

FT/IR-460 FT/IR-470 FT/IR-480
Measurable W.N. range

7800 - 350 cm -1

15000 - 2200 cm -1 (option, NIR model)

5000 - 220 cm -1 (factory option, Far-IR model)

Resolution 0.9, 2, 4, 8, 16 cm -1  0.5, 1, 2, 4, 8, 16 cm -1
Optical system Single beam
Aperture diameter  fixed
Sample compartment 175 (W) x 255 (D) x 170 (H) mm
Beam diameter onto sample 4 mmf
Light path in sample compartment Center focus, light axis 70 mmH
Interferometer 45 deg. incident Michelson interferometer, corner cube mirror, sealed structure, purgeable
Interferometer drive mechanism Mechanical bearing, electromagnetic drive
Interferometer drive speed  Variable by software
Rapid scan Option (10 spectra/sec., 16 cm -1 resolution)
Beam splitter  Ge coated KBr substrates, CaF 2 (option, NIR model), CsI (factory option, Far-IR model)
Interferometer window material KRS-5
Light source High-intensity light source, Halogen lamp (Option)
 Detector DLATGS with Peltier element(KRS-5), MCT-N (- 750 cm -1 ) option, MCT-M (- 650 cm -1 ) option, MCT-W (- 450 cm -1 ) option, InSb option, Silicon-photodiode (option). Up to two detectors can be located simultaneously.
S/N ratio 15000:1  22000:1 24000:1
(4 cm -1 , 1 min, near 2200 cm -1 , p-p measurement with KRS-5 window)
GAIN switching Manual operation at 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048 times (12 steps)
Auto gain at 1, 2, 4, 8, 16, 32, 64, 128, 256, 512 (10 steps)
A/D converter 16 bit + gain-ranging  18 bit + gain-ranging
100% T line flatness less than 100 1.0% (4000 - 700 cm-1, continuous measurement)
Dimensions 590(W) x 550(D) x 257(H) mm
Weight Approx. 41 kg
Power requirement AC 100~240/font>10 V, 50 or 60H,

Standard Accessories

Main Unit 1 off
Spectra Manager Software with Quick Start program
Validation for FT/IR-400 Series (Manual Version requires 6713-F429A filter for validation)
Quantitative software
Instruction Manual 1 copy
Pin for setting accessories 2 pcs.
Power cable 1 pc.
Polystyrene film 1 pc.
Spare fuse 4 pcs.
ARAS Accessory Unit

Go to top of page

Click here to see the FT/IR-400Plus Series specification sheet - Acrobat Format (28Kb)

Ordering Information (UK & Eire only)

PART NUMBER

DESCRIPTION

6812-J006A

FT/IR-460 PLUS FT/IR Spectrometer

6812-J007A

FT/IR-470 PLUS FT/IR Spectrometer

6812-J008A

FT/IR-480 PLUS FT/IR Spectrometer

6812-J034A

FT/IR-470 PLUS FT/IR Spectrometer (Far IR model)

6812-J035A

FT/IR-480 PLUS FT/IR Spectrometer (Far IR model)

6812-U006A

FT/IR-460 PLUS Automated Validation Spectrometer System

Includes:

6812-J006A FT/IR-460 PLUS Spectrometer

6748-F143A Validation autosampling

1537 SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card

2930U-FTIR AHA-2930U Adaptec PCI card

Requires: A suitably configured PC

6812-U006M

FT/IR-460 PLUS Manual Validation Spectrometer System

Includes:

6812-J006A FT/IR-460 PLUS Spectrometer

6713-F429A Cut off filter for FTIR manual validation

1537 SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card

2930U-FTIR AHA-2930U Adaptec PCI card

Requires: A suitably configured PC

6812-U007A

FT/IR-470 PLUS Automated Validation Spectrometer System

Includes:

6812-J007A FT/IR-470 PLUS Spectrometer

6748-F143A Validation autosampling

1537 SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card

2930U-FTIR AHA-2930U Adaptec PCI card

Requires: A suitably configured PC

6812-U007M

FT/IR-470 PLUS Manual Validation Spectrometer System

Includes:

6812-J007A FT/IR-470 PLUS Spectrometer

6713-F429A Cut off filter for FTIR manual validation

1537 SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card

2930U-FTIR AHA-2930U Adaptec PCI card

Requires: A suitably configured PC

6812-U008A

FT/IR-480 PLUS Automated Validation Spectrometer System

Includes:

6812-J008A FT/IR-480 PLUS Spectrometer

6748-F143A Validation autosampling

1537 SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card

2930U-FTIR AHA-2930U Adaptec PCI card

Requires: A suitably configured PC

6812-U008M

FT/IR-480 PLUS Manual Validation Spectrometer System

Includes:

6812-J008A FT/IR-480 PLUS Spectrometer

6713-F429A Cut off filter for FTIR manual validation

1537 SCSI-1 to SCSI-2 Cable for AHA-2930U PCI card

2930U-FTIR AHA-2930U Adaptec PCI card

Requires: A suitably configured PC

Go to top of page

Optional Accessories

PART NUMBER
DESCRIPTION

6748-F143A

Validation autosampling (Factory Fitted), includes validation software, automatic polystyrene and cut off filter insertion filter wheel mechanism within the instrument

6713-F429A

Filter for FTIR manual validation

4880-0523A

Macro command program

4880-0702X

JASCO Library search program

4880-0703X

Interval scanning program

4880-0701X

Quantitative analysis

2930U-FTIR

AHA2930U Adaptec PCI card for FT/IR-400 and 600 series

1537

SCSI-1 to SCSI-2 Cable for AHA-2930U Adaptec PCI card

6748-J202A

MCT (Mercury Cadmium Telluride) Detector mid range 15000-650 cm-1 includes detector switching mechanism Note: Requires Liquid Nitrogen Cooling

6748-J203A

MCT (Mercury Cadmium Telluride) Detector wide range 15000-450 cm-1 includes detector switching mechanism Note: Requires Liquid Nitrogen Cooling

6749-J213A

InSb, requires liquid N2 (15,000-1000cm-1 range) with mirror switching mechanism

6749-J211A

DTGS (Polyethylene window) 700-50cm-1 range with mirror switching mechanism

6749-J212A

MCT (mid range), LN2 (10,000-650cm-1 range) with mirror switching mechanism

6786-J006A

IRT-30-32E InfraRed Microscope x32 Cassegrainian for FT/IR-400 Series

6786-J005A

IRT-30-16E InfraRed Microscope x16 Cassegrainian for FT/IR-400 Series

6786-J033A

IPS-30E IR Profile System X-Y-Z Stage autofocus & Software

6694-J122A

PL-200 Infra-Red polarisation accessory (factory option)

6690-J108A

ATR-JC-Z ATR Objective, ZnSe Prism Cassegrain

6690-J111A

ATR-VZ ATR Objective, ZnSe Prism (Viewable type) Cassegrain

6690-J109A

ATR-JC-G ATR Objective, Ge Prism Cassegrain

6694-J133A

PL-E Polariser for visible observation 

6668-J111A

RAS-200 Grazing angle reflectance attachment (PL-200 is also required)

6668-J024A

RAS-500 Grazing angle reflectance attachment (PL-200 is also required)

 