MAIN MENU

CATALOG INDEX
BY ALPHABETICAL
ORDER

CATALOG INDEX
BY DEPARTMENT

For more info:
JSi@jsits.com

- [ 8 Eight Channel
Temperature Logger -
SmartReader 8 ]
- [ Data Logger & Software
Packages ]
- [ Display STARLOGGER
Model 6004-2 ]
- [ Eight-Channel Tempe-
rature Info Logger -

SmartReader Plus 8 ]
- [ Electric Current and
Temperature Info Logger
- SmartReader Plus 3 ]
- [ Electric Current and
Temperature Logger -
SmartReader 3 ]
- [ Hygro-Thermometer
Anemometer/Data Logger ]
- [ MACRO Data Logger
Model 7000 ]
- [ MACRO Tester model
7805A ]
- [ Memory Card STAR
LOGGER Model 6004-3 ]
- [ Multi-channel Thermo-
couple Info Logger -
SmartReader 6 ]
- [ Multi-channel Thermo-
couple Info Logger -
SmartReader Plus 6 ]
- [ Pressure, Temperature
and RH Info Logger -
SmartReader 4 ]
- [ Pressure, Temperature,
and RH Info Logger -
SmartReader Plus 4 ]
- [ Process Signal Info
Logger - SmartReader
Plus 7 ]
- [ Process Signal Logger -
SmartReader 7 ]
- [ Pulse Info Logger -
SmartReader Plus 9 ]
- [ Pulse Logger - Smart-
Reader 9 ]
- [ RF Remote Site
Monitoring Products ]
- [ Rugged MS-DOS 5.0
Hand-Held PC ]
- [ Standard STARLOGGER
Model 6004-1 ]
- [ Temperature and Rela-
tive Humidity Logger -
SmartReader 2 ]
- [ Temperature and Rela-
tive Humidity Logger -
SmartReader Plus 2 ]
- [ Temperature Info
Logger - SmartReader
Plus 1 ]
- [ Temperature Logger -
SmartReader 1 ]
- [ Thermocouple Info
Logger - SmartReader
Plus 5 ]
- [ Thermocouple Logger -
SmartReader 5 ]

Electric Current and Temperature Logger - Smart Reader 3
Smart Reader 3 is a data logger designed for easy recording of electrical A.C. current. You can use this logger with up to three external current probes for recording three-phase systems or related equipment simultaneously. The probes allow accurate readings to be taken without any need for breaking circuity.

Applications :

Monitoring air conditioning or mechanical equipment, determining tenant electrical consumption; tracking environmental conditions. Order one or more Amprobe A60FL or A70FL current probes to work with the SmartReader 3. See specifications below for the selectable ranges each probe offers.

Specifications :

  • Size : 107 x 74 x 22 mm (4.2" x 2.9" x 0.9")
  • Weight : 110 grams (5 ounces)
  • Case Material : Noryl Plastic
  • Operating Limits : -45°C to 70°C (-50°F to 160°F) and 0 to 95% Relative Humidity (non-condensing)
  • Clock-Accuracy : +/-8 seconds per day plus one sampling interval
  • Battery : 3.6 volt Lithium, 1 Amp-Hour
  • Power Consumption : 5 to 10 microamps (continuous)
  • Battery Life : Ten years (Factory Replaceable)
  • External Connector : Removable screw-type terminal strip with Common (-) connection
  • Memory Size : 32,768 readings
  • Sampling Methods :
    1. Continuous (First-in, First-out)
    2. Stop when full (Fill-then-stop)
  • Sampling Rates : User selectable rates from every 8 seconds to once a week
  • Resolution : 8 bits (1 part in 256)
  • PC Hardware Requirements : IBM PC or 100% compatible with: at least one serial port; an IBM CGS, EGA, HGA, VGA, or other adapter capable of emulating thses standards
  • Software Requirements :
    1. TrendReader for DOS-MS DOS version 3.0 or later and at least 512 K of RA memory. TrendReader for DOS supports a wide range of printers and plotters.
    2. TrendReader for Windows-Windos version 3.1 or later already running with at least 2MB of RAM memory and 2MB of hard drive disk space
  • Product Approvals : Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada and of Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC).
  • Resistance to X-Rays : Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.1337 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"

Internal Temperature Sensor (common on all models):

  • Type : Negative Temperature Coefficient Thermistor
  • R25 Value : 10,000 ohms
  • Tolerance (sensor only) : +/-0.2°C, over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to 158°F).
  • Range : -40 to 70°C (-40 to 158°F)
  • Resolution : 0.4°C (0.7°F). Better than 1°C (1.8°F) between -25°C (-13°F) and 70°C (158°F). Better than 2.0°C (3.6°F) between -40°C (-40°F) and -25°C (-13°F).
CAT. NO.
_
DESCRIPTION
_
ACRSR003-0....... Electric current and temperature logger.
ACRA60FL1-0.... Amprobe A60FL current probe.
ACRA70FL1-0.... Amprobe A70FL current probe.
ACRTRSFW-0.... Trendreader software with IC-100 cable