Benchmark Microplate ELISA Reader
- Operating panel: Membrane keypad with eight keys
- Display: 4 lines x 16 characters LCD
- Warm-up time: 3 minutes
- Read times: 7 seconds single wavelength; 15 seconds dual wavelength
- Mixing capability: Yes
- Compatible plates: Polystyrene flat, U- and V-bottom, PVC flex
plates
- Data storage: Data and reports from last 10 plates read and system
- configuration parameters
- Report types: Raw data, absorbance, matrix, limit, cutoff, concentration
- Printer: 20 column, 5 x 7 dot-matrix printer built-in
- Computer interface: Bi-directional RS232 serial communication port
- Memory back-up: 5-year lithium battery
- OPTICAL
- Optical light source: 20 watt Tungsten halogen; 5,000 hour life
- Spectral range: 340.750 nm
- Filter capacity: Six
- Standard filters: 340 nm, 405 nm, 415 nm, 655 nm
- Optional Filters: User choice
- TECHNICAL
- Technical indication range: 0.000 - 4.000 O.D.
- Resolution: 0.001 O.D.
- Accuracy: (1.0% or 0.015 at O.D.=1 for single wavelength reading);
- (2.0% or 0.020 at O.D.=1 for dual wavelength reading)
- Linearity: Less than 2% in the ranges of 340-399 nm (0.000-2.000
O.D.)
- and 400-750 nm (0.000-3.000 O.D.) less than 3.5% in the range of
- 400-750 nm from 0.000-4.000 O.D.
- Reproducibility: Less than 2.0% or 0.005 O.D. in the range
- of 340-399 nm (0.000-2.000 O.D.); Less than 1.0% or 0.005 O.D.
- in the range of 400-750 nm (0.000.3.000 O.D.); Less than 3.5%
- in the range of 400-750 nm (0.000-4.000 O.D.)
- Stability and drift: Automatic calibration before each plate reading
- PHYSICAL
- Incubator set point: 37 ━C (0.5 ━C at ambient temperature)
- Well-to-well uniformity: 0.5 ━C at ambient temperature
- Warm-up time: 30 minutes at ambient temperature
- Physical line voltage: 90-264 VAC, 50-60 Hz
- Power consumption: 100 VA max
- Dimensions: 316 x 286 x 124 mm (W x D x H)
- Weight: 6 Kg
- Operating temperature: 5 to 35 ━C
- Storage temperature: -20 to 50 ━C operating and 0-95%
- non-condensing storage humidity
- Ordering Information
- Catalog No. Product Description
- 170-6850 Benchmark Microplate Reader,
- 100-240 V, 50/60 Hz, includes 340, 405,
415 and 655 nm filters (installed) and two
- additional filters to be chosen from the list
- below at time of purchase, one roll of printer
- paper, spare fuses, dust cover, instructions
- 170-6906 340 nm Filter
- 170-6907 405 nm Filter
- 170-6908 415 nm Filte
- 170-6909 450 nm Filter
- 170-6910 490 nm Filter
- 170-6911 540 nm Filter
- 170-6912 550 nm Filter
- 170-6913 570 nm Filter
- 170-6914 595 nm Filter
- 170-6915 630 nm Filter
- 170-6916 655 nm Filter
- 170-6852 Replacement Lamp
- 170-6624 Printer Paper, 4 rolls