Benchmark Microplate ELISA Reader

  • Operating panel: Membrane keypad with eight keys
  • Display: 4 lines x 16 characters LCD
  • Warm-up time: 3 minutes
  • Read times: 7 seconds single wavelength; 15 seconds dual wavelength
  • Mixing capability: Yes
  • Compatible plates: Polystyrene flat, U- and V-bottom, PVC flex plates
  • Data storage: Data and reports from last 10 plates read and system
  • configuration parameters
  • Report types: Raw data, absorbance, matrix, limit, cutoff, concentration
  • Printer: 20 column, 5 x 7 dot-matrix printer built-in
  • Computer interface: Bi-directional RS232 serial communication port
  • Memory back-up: 5-year lithium battery
  • OPTICAL
  • Optical light source: 20 watt Tungsten halogen; 5,000 hour life
  • Spectral range: 340.750 nm
  • Filter capacity: Six
  • Standard filters: 340 nm, 405 nm, 415 nm, 655 nm
  • Optional Filters: User choice
  • TECHNICAL
  • Technical indication range: 0.000 - 4.000 O.D.
  • Resolution: 0.001 O.D.
  • Accuracy: (1.0% or 0.015 at O.D.=1 for single wavelength reading);
  • (2.0% or 0.020 at O.D.=1 for dual wavelength reading)
  • Linearity: Less than 2% in the ranges of 340-399 nm (0.000-2.000 O.D.)
  • and 400-750 nm (0.000-3.000 O.D.) less than 3.5% in the range of
  • 400-750 nm from 0.000-4.000 O.D.
  • Reproducibility: Less than 2.0% or 0.005 O.D. in the range
  • of 340-399 nm (0.000-2.000 O.D.); Less than 1.0% or 0.005 O.D.
  • in the range of 400-750 nm (0.000.3.000 O.D.); Less than 3.5%
  • in the range of 400-750 nm (0.000-4.000 O.D.)
  • Stability and drift: Automatic calibration before each plate reading
  • PHYSICAL
  • Incubator set point: 37 ━C (0.5 ━C at ambient temperature)
  • Well-to-well uniformity: 0.5 ━C at ambient temperature
  • Warm-up time: 30 minutes at ambient temperature
  • Physical line voltage: 90-264 VAC, 50-60 Hz
  • Power consumption: 100 VA max
  • Dimensions: 316 x 286 x 124 mm (W x D x H)
  • Weight: 6 Kg
  • Operating temperature: 5 to 35 ━C
  • Storage temperature: -20 to 50 ━C operating and 0-95%
  • non-condensing storage humidity
  • Ordering Information
  • Catalog No. Product Description
  • 170-6850 Benchmark Microplate Reader,
  • 100-240 V, 50/60 Hz, includes 340, 405,
    415 and 655 nm filters (installed) and two
  • additional filters to be chosen from the list
  • below at time of purchase, one roll of printer
  • paper, spare fuses, dust cover, instructions
  • 170-6906 340 nm Filter
  • 170-6907 405 nm Filter
  • 170-6908 415 nm Filte
  • 170-6909 450 nm Filter
  • 170-6910 490 nm Filter
  • 170-6911 540 nm Filter
  • 170-6912 550 nm Filter
  • 170-6913 570 nm Filter
  • 170-6914 595 nm Filter
  • 170-6915 630 nm Filter
  • 170-6916 655 nm Filter
  • 170-6852 Replacement Lamp
  • 170-6624 Printer Paper, 4 rolls