Air quality monitor Yes_206 for CO2 and temperature

AxSys Remote Station제품 사양

  • 넓은 LCD 표시창
    화면에 모든 측정치값 표시
    빠르고 읽기쉬운 화면 :
    • CO2 in % or PPM
    • Temperature C or F
    • Elevation in FT or M
  • 4 AA Batteries
    배터리 사용시 48시간 사용가능
    or use AC/DC power supply for continuous monitoring.
  • Elevation Correction
    Take the guess work out of readings ~ enter current elevation, and the sensor automatically adjusts.
  • Quick, easy calibration
    No parts to lose. Just connect the gas and make any necessary adjustments through the control bottons.
  • Attractive case
    Small, modern design complete with a "kickstand" for visible readings at glance.

Applications

  • Assessment/Investigation of ventilation related problems in homes and buildings.
  • Proactive monitoring of ventilation rates to avoid IAQ problems.
  • Before and after verification tool for installation of vatilation or heat recovery ventilator upgrade.
  • Measurement of air fluctuation rates using CO2 as a tracer gas.
  • Maintenance/serviec tool for HVAC Systems
  • Air balancing

사양

  • Operating conditions
    • 작동온도 범위: +32 to +122F(0 to +50C)
    • 작동습도 범위: 5 to 95% RH non-condensing
    • 작동 압력 범위: 1.5% local mean pressure range
    • 저장 온도 범위: -40 to +140F (-40 to +60C)
  • Temperature channel
    • 온도 범위: +32 to +122F (0 to +50C)
    • 해상도: 0.1F/0.1C
    • 정밀도: 0.5C of readings
    • Response time: <30 sec.
  • Power source
    • 4 AA batteries (48 hours - Alkaline)
    • 6V DC adapter (included)
  • CO2 channel
    • CO2 농도 범위: 0 to 9.999ppm
    • 해상도: 1ppm
    • 정밀도: 5% of readings or 50ppm whichever is greater
    • Repeatability: 20ppm
    • Maximum drift (per year): 20ppm
    • Warm-up time @ 22C: <2 nim.
    • Response time: <30 sec.
    • Temperaturee dependance: 0.1% per C or 1ppm per C whichever is greater
    • Calibration infield zero, using arbitrary CO2 concentration
    • Calibration internal (recommended): once every three years
    • Gas law correction: elevation adjustment & temp compensation
  • Analog output
    • CO2 ~ 0-4 VDC, 1ppm/mV
    • Temperature ~ 0-4 VDC scale
    • Output impedance ~ 1 KOhm
  • Digital output
    • Display ~ LCD with independent display of CO2 and temperaturre readings
CAT. NO. DESCRIPTION
YES206-000...... Indoor air quality monitor for CO2 and temperature